80C196KB USER’S GUIDE
PVER is a 1 if the data program was successful. PVER
is a 0 if the data program was unsuccessful. Figure 16-7
shows the relationship of PALE, PROG, and PVER to
the Command/Data path on Ports 3 and 4 for the Data
Program Command.
Data Verify Command
When the Data Verify Command is sent, the slaves in-
dicate correct or incorrect verification of the previous
Data Program Command by driving one bit of Ports 3
and 4. A 1 indicates a correct verification, and a 0 indi-
cates incorrect verification. The SID (Slave I.D) of each
slave determines which bit of Ports 3 and 4 will be
driven. For example, a SID of 0001 would drive Port
3.1. PROG governs when the slaves drive the bus. Fig-
ure 16-8 shows the relationship of ports 3 and 4 to
PALE and PROG.
A Data Verify Command is always preceded by a Data
Program Command in a programming system with as
many as 16 slaves. However, a Data Verify Command
does not have to follow every Data Program Com-
mand.
Word Dump Command
When the Word Dump Command is issued, the
87C196KB adds 2000H to the address field of the com-
mand and places the value at the new address on Ports
3 and 4. For example, when the slave receives the com-
mand 0100H, it will place the word at internal address
2100H on Ports 3 and 4. PROG governs when the slave
drives the bus. The Timings are the same as shown in
Figure 16-7.
Note that the Word Dump Command only works when
a single slave is attached to the bus. Also, there is no
restriction on commands that precede or follow a Word
Dump Command.
Gang Programming With the Slave
Programming Mode
Gang Programming of 87C196KBs can be done using
the Slave Programming Mode. There is no 87C196KB
based limit on the number of devices that may be
hooked to the same Port 3 and 4 data path for gang
programming.
If more than 16 devices are being gang programmed,
the PVER outputs of each chip can be used for verifica-
tion. The master programmer can issue a Data Pro-
gram Command, then either watch every device’s error
signal, or AND all the signals together to form a sys-
tem PVER.
270651 – 75
Figure 16-8. Ports 3 and 4 to PALE and PROG
91
数控原理与维修
http://www.agreenleaf.cn
Содержание 80C196KB Series
Страница 1: ...November 1990 80C196KB User s Guide Order Number 270651 003 http www agreenleaf cn...
Страница 59: ...80C196KB USER S GUIDE Figure 11 7 Ideal A D Characteristic 270651 37 55 http www agreenleaf cn...
Страница 60: ...80C196KB USER S GUIDE Figure 11 8 Actual and Ideal Characteristics 270651 38 56 http www agreenleaf cn...
Страница 61: ...80C196KB USER S GUIDE Figure 11 9 Terminal Based Characteristic 270651 39 57 http www agreenleaf cn...
Страница 70: ...80C196KB USER S GUIDE Figure 13 5 Reset Sequence 80C196KB Reset Sequence 270651 45 66 http www agreenleaf cn...
Страница 83: ...80C196KB USER S GUIDE 270651 80 Figure 15 14 AC Timing Diagrams 79 http www agreenleaf cn...
Страница 84: ...80C196KB USER S GUIDE 270651 81 270651 84 Figure 15 14 AC Timing Diagrams Continued 80 http www agreenleaf cn...