80C196KB USER’S GUIDE
pwm program:
ldb ioc2,
#
0c0h
; flush entire cam
ldb hso command,
#
0ceh
; program timer2 reset time
ld hso time,PWM period
nop
; delay eight state times before
nop
; next load
nop
nop
ldb hso command,
#
0e6h
; HSO 0/1 high, locked, timer2 as
; reference
ld hso time,PWM period
; set hso high on t2rst
nop
nop
nop
nop
ldb hso command,
#
0e7h
; HSO 2/3 high, locked, timer2
; as reference
ld hso time,PWM period
; set hso high on t2rst
nop
nop
nop
nop
ldb hso command,
#
0c0h
; set HSO.0 low, locked, timer2
; as reference
ld hso time,pwm0timl
; HSO.0 time low
nop
nop
nop
nop
ldb hso command,
#
0c1h
; set HSO.1 low, locked, timer2
; reference
ld hso time,pwm1timl
; HSO.1 time low
nop
nop
nop
nop
ldb hso command,
#
0c2h
; set HSO.2 low, locked,timer2
; as reference
ld hso time,pwm2timl
; HSO.2 time low
nop
nop
nop
nop
ldb hso command,
#
0c3h
; set HSO.3 low, locked,timer2
; as reference
ld hso time,pwm3timl
; HSO.3 time low
ret
end
Figure 9-6. Generating Four PWMs Using Locked Entries
(Continued)
46
数控原理与维修
http://www.agreenleaf.cn
Содержание 80C196KB Series
Страница 1: ...November 1990 80C196KB User s Guide Order Number 270651 003 http www agreenleaf cn...
Страница 59: ...80C196KB USER S GUIDE Figure 11 7 Ideal A D Characteristic 270651 37 55 http www agreenleaf cn...
Страница 60: ...80C196KB USER S GUIDE Figure 11 8 Actual and Ideal Characteristics 270651 38 56 http www agreenleaf cn...
Страница 61: ...80C196KB USER S GUIDE Figure 11 9 Terminal Based Characteristic 270651 39 57 http www agreenleaf cn...
Страница 70: ...80C196KB USER S GUIDE Figure 13 5 Reset Sequence 80C196KB Reset Sequence 270651 45 66 http www agreenleaf cn...
Страница 83: ...80C196KB USER S GUIDE 270651 80 Figure 15 14 AC Timing Diagrams 79 http www agreenleaf cn...
Страница 84: ...80C196KB USER S GUIDE 270651 81 270651 84 Figure 15 14 AC Timing Diagrams Continued 80 http www agreenleaf cn...