Care and maintenance
176
ECG cable 5 leads (code 7900-5) 2.5 m.
Set of external defibrillation pads (code 79001) 2.5 m.
SpO
2
finger sensor cable (code 12556) + SpO
2
finger cable extensor (code
21176) 2.5 m.
Pacemaker cable (code 80208) 2.5 m.
WARNING:
Using cables, transducers and accessories different from the ones specified
above, except for the ones sold by Instramed as replacement pieces, may
result in emission increase or immunity decrease of the equipment.
The CardioMax must not be used too close to or piled over other equipment.
When the equipment is used in a surgical procedure simultaneously with an
electric scalpel, there is a risk of burnouts if a defect in the connection of
the neutral electrode of the high frequency equipment matches a defect in
the CardioMax's ECG socket. This type of accident will only occur when the
defects occur simultaneously, as the CardioMax's ECG socket is electrically
protected against risks of burnouts, being completely insulated.
Electromagnetic emissions
Directives and manufacturer declaration - electromagnetic emissions
The CardioMax is intended for use in the specific electromagnetic environment below. The customer or user of the defibrillator is
advised to ensure that it is used in such an environment.
Tests
Compliance
Electromagnetic environment - directives
RF Emissions ABNT NBR IEC CISPR11
Group 1
The CardioMax only uses RF power for its internal functions.
Nevertheless, its RF emissions are very low and are not likely
to cause any interference in nearby electronic equipment.
RF Emissions ABNT NBR IEC CISPR11
Class B
The CardioMax is suited for use in any establishment.
This includes residential establishments and those directly
connected to the public network of distribution of low voltage
electricity which supply domestic use buildings.
Harmonics Emissions IEC 61000-3-2
Class A
Voltage fluctuations/flicker emissions IEC
61000-3-3
Complies
NOTE: It is of paramount importance that the true efficacy of the RF shielding and the true attenuation of the RF filter of the shielded
location are checked to ensure that they meet or exceed the minimum values specified.
AVISO: O CardioMax é adequado para utilização em ambientes
profissionais de cuidado à saúde.
ATENÇÃO: Não utilize o equipamento na presença de aparelhos de
ressonância magnética. Devem ser adotadas medidas para minimizar a
interferência de equipamentos cirúrgicos de alta frequência.