93
Figure 67. MatrIIX Pressure Governor Module
Figure 68. Governor Module Interface Layout
The matrIIx/pressure governor module installs on the Hale provided bracket located on the front
of the pump directly above the circuit breaker box and Autolube assemblies (right most module).
Connect the module according to Table 48.
Table 48. MatrIIx/Pressure Governor Module Wiring (From/To Listing)
Module Connector/Pin (From)
Sensor Connector/Pin (To)
A Keyed Connector (Mates with Grey Harness Connector)
1
(Power)
[Input]
Circuit Breaker Box, Connector 1 Pin 3
2
(CAN High)
[Buss]
Green CAN Bus Connector
3
(CAN Shield)
[Buss]
Green CAN Bus Connector
4
(Pump Engaged Interlock)
[Input]
OEM Connection To Apparatus
5
(Throttle Interlock)
[Input]
OEM Connection To Apparatus
6
(Auxiliary Interlock)
[Input]
OEM Connection To Apparatus
7
(Delay Relay Common)
[Input]
N/C
8
(Delay Relay Normally Open) [Output]
N/C
9
(Alarm Out)
[Output]
N/C
10 (Auxiliary Input/Output)
[I/O]
N/C
11 (CAN Low)
[Buss]
Green CAN Bus Connector
12 (Ground)
[Input]
Main Ground Stud (On Pump Body)
Содержание Hale Sam
Страница 2: ......
Страница 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Страница 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Страница 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Страница 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Страница 41: ...21 Figure 18 SAM Speaks Diagram...
Страница 42: ......
Страница 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Страница 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Страница 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Страница 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Страница 220: ...200 THIS PAGE INTENTIONALLY BLANK...