5-2
5
5.3
TROUBLESHOOTING
Troubleshooting is broken down into self test errors and operating errors
that are caused during usage.
5.3.1 Self Test Errors
The 4809A, 4819A and 4899A indicate self test errors by blinking one or
more of its LEDs at a 2 cps rate. Verify the error by turning the unit off
for 10 seconds, disconnect the unit from any other equipment and then
turn the power back on. If the error persists it is a true self test error. The
self test error codes and their most likely problems are listed in Table 5-1.
5.3.2 Operating Failures
Use the fault isolation information in Table 5-2 to narrow the operational
problem down to a specific area. The majority of installation faults can
be fixed by following the table and making the necessary corrections to
the installation wiring or the program. Failures after the unit has been
running a while can be isolated by first substituting a known good unit or
output/input channel.
WARNING
If the fault isolation procedure requires internal
measurements, always remove power when dis-
assembling or assembling the unit. Use extreme
caution during troubleshooting, adjustments, or
repair to prevent shorting components and causing
further damage to the unit.