User Manual 3.4
INTEGRA Biosciences
Page 67
ENGLISH
SAFETY COVER
Hood to protect the operator against access to vessel lid during some
process phases. Above 80°C. vessel temperature, it is always closed
and locked. Open/Close status is monitored by a safety cover closed
sensor.
SAFETY COVER LOCK
Box in which the safety cover sensor is placed in.
SAFETY COVER SENSOR
Magnetic sensor that determines if the safety cover is open or closed.
SAFETY SLITS
These limit the pressure in the vessel to 1.75 bar and are located at
the edge of the vessel lid. Covered by support plates.
SAFETY VALVE
This device limits pressure within the vessel to 1.75 bar (+10% toler-
ance) and is located on the vessel lid.
SERIAL PORT CONNEC-
TORS
Support internal and external devices that require serial data transmis-
sion (for example, RS232).
SOFT KEYS
These keys are situated below the GUI and used to select screen
options.
SOFT KEYS PROTECTION
COVER
Magnetic front cover. Protects the electronics beneath the soft keys
from moisture.
START DISPLAY
Screen that appears when the instrument is switched on. This allows
the user to select the six main options used by MediaClave (MEDIA-
CLAVE, AUTOCLAVE, WATERBATH, CLEANING, LANGUAGE and
PARAMETER).
STEP
This program function enables the operator to interrupt a cycle phase
manually and proceed to the next phase in the program cycle. This
cannot be used during a cooling phase.
STERILISATION TOLER-
ANCE
Specifies the range of temperatures at which the vent valve closes
during the sterilisation phase of a program cycle.
STIRRING SPEED
A program parameter specifying the speed at which the product is
stirred. Possible values are 1 and 2.
TEMPERATURE CALIBRA-
TION
External method for calibrating the MediaClave (performed by an IBS
service technician).
TEST PRINT
A performance test that checks the functionality of the printer.
TYPE PLATE
Located to the rear of the instrument, this specifies compatibility with
network voltage and fuse ratings as well as type and serial number.
VESSEL
Container (Pressure vessel) in which the cuvette can be entered
VESSEL LID
Stainless steel lid with ports for filling, dispense, temperature sensor
and safety valve. It is connected to the vessel by a bajonet coupling.
Open/close status is monitored by a safety cover closed sensor.
WATER BATH
Program suite used for operation of MediaClave as a water bath.
WATER CONTROL
Step in the AUTOCLAVE program to check the heating water level.
VESSEL LID GRIPS WHITE
Located on the MediaClave vessel lid, these are turned anticlockwise
to open the vessel lid.
Содержание MediaClave
Страница 1: ...User Manual 3 4 Bedienungsanleitung 3 4 Mode d emploi 3 4...
Страница 6: ...Table of contents INTEGRA Biosciences PAGE IV...
Страница 12: ...MediaClave overview INTEGRA Biosciences Page 6...
Страница 18: ...MediaClave overview INTEGRA Biosciences Page 12...
Страница 30: ...MediaClave overview INTEGRA Biosciences Page 24...
Страница 48: ...MediaClave overview INTEGRA Biosciences Page 42...
Страница 56: ...MediaClave overview INTEGRA Biosciences Page 50...
Страница 68: ...MediaClave overview INTEGRA Biosciences Page 62...
Страница 70: ...MediaClave overview INTEGRA Biosciences Page 64...
Страница 74: ...MediaClave overview INTEGRA Biosciences Page 68...