80030112-0601ffff
Sensor [SensorElementName] has asserted. (SMM Mode, SMM Monitor)
Explanation:
This message is for the use case when an implementation has detected a Sensor has asserted.
May also be shown as 800301120601ffff or 0x800301120601ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0508
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
8007010f-2201ffff
Sensor [SensorElementName] has transitioned from normal to non-critical state. (GPT Status)
Explanation:
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 8007010f2201ffff or 0x8007010f2201ffff
Severity:
Warning
Alert Category:
Warning - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0520
SNMP Trap ID:
60
Automatically notify Support:
No
User response:
1.
Check the IBM support site for service bulletins or firmware updates that apply to this GPT error.
2.
Set the UEFI setting DISK GPT Recovery to Automatic.
3.
Replace the corrupt disk.
8007010f-2582ffff
Sensor [SensorElementName] has transitioned from normal to non-critical state. (I/O
Resources)
Explanation:
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 8007010f2582ffff or 0x8007010f2582ffff
Severity:
Warning
Alert Category:
Warning - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0520
SNMP Trap ID:
60
Automatically notify Support:
No
User response:
Complete the following step to solve PCI I/O resource errors:
1.
Go to F1 Setup
2.
System Settings
3.
Device and I/O ports
4.
PCI 64 bit Resource and choose enable
80030112-0601ffff • 8007010f-2582ffff
Appendix A. Integrated management module II (IMM2) error messages
389
Содержание x3100 M5 Type 5457
Страница 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 679: ...Taiwan Class A compliance statement Notices 663 ...
Страница 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 687: ......
Страница 688: ... Part Number 00V9791 Printed in USA 1P P N 00V9791 ...