202-801-000
MemStr Test Aborted
Explanation:
Internal program error.
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Turn off and restart the system.
2.
Make sure that the DSA Diagnostic code is at the latest level.
3.
Run the test again.
4.
If the system has stopped responding, turn off and restart the system.
5.
Check the system firmware level and upgrade if necessary.
6.
Run the memory diagnostic to identify the specific failing DIMM.
7.
If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for
the next corrective action.
Related Links:
v
v
v
202-802-000
MemStr Test Aborted
Explanation:
Memory size is insufficient to run the test. At least 1 GB is required.
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
Related Links:
v
v
v
202-801-000 • 202-802-000
Appendix C. DSA diagnostic test results
623
Содержание x3100 M5 Type 5457
Страница 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 679: ...Taiwan Class A compliance statement Notices 663 ...
Страница 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 687: ......