806f020d-0404ffff
Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 4)
Explanation:
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0404ffff or 0x806f020d0404ffff
Severity:
Warning
Alert Category:
System - Predicted Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0168
SNMP Trap ID:
27
Automatically notify Support:
Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b.
Cable from the system board to the backplane
3.
Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive
number)
806f020d-0405ffff
Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 5)
Explanation:
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0405ffff or 0x806f020d0405ffff
Severity:
Warning
Alert Category:
System - Predicted Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0168
SNMP Trap ID:
27
Automatically notify Support:
Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b.
Cable from the system board to the backplane
3.
Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive
number)
806f020d-0404ffff • 806f020d-0405ffff
420
System x3100 M5 Type 5457: Installation and Service Guide
Содержание x3100 M5 Type 5457
Страница 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 679: ...Taiwan Class A compliance statement Notices 663 ...
Страница 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 687: ......
Страница 688: ... Part Number 00V9791 Printed in USA 1P P N 00V9791 ...