Note:
You may need to slightly lift up the cage in order to press and hold the
retaining tab.
6.
Install the hard disk drive fan duct onto the hard disk drive cage (see
“Replacing the hard disk drive fan duct” on page 225).
7.
Stand the server back up in its vertical position.
8.
Install the hot-swap hard disk drives that you removed from the hard disk
drive cage (see “Replacing a hot-swap hard disk drive” on page 220).
9.
Install the lower bezel (see “Replacing the lower bezel” on page 190).
10.
Install and lock the side cover (see “Replacing the side cover” on page 182).
11.
Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Removing the battery holder from 5U server model
Use this information to remove the battery holder from 5U server model
To remove the battery holder from the 5U server model with hot-swap power
supplies, complete the following steps.
1.
Read the safety information in “Safety” on page vii and “Installation
guidelines” on page 35.
2.
Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3.
Unlock and remove the side cover (see “Removing the side cover” on page 38).
4.
Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention:
Do not allow the server to fall over.
5.
Remove the battery holder and bracket from the chassis by unscrewing the
screw.
Hard disk drive cage
Release tab
Figure 99. Rotating hard disk drive cage into chassis for 5U server model with hot-swap
power supplies
198
System x3100 M5 Type 5457: Installation and Service Guide
Содержание x3100 M5 Type 5457
Страница 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 679: ...Taiwan Class A compliance statement Notices 663 ...
Страница 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 687: ......
Страница 688: ... Part Number 00V9791 Printed in USA 1P P N 00V9791 ...