806f0513-2582ffff
A PCI SERR has occurred on system [ComputerSystemElementName]. (PCIs)
Explanation:
This message is for the use case when an implementation has detected a PCI SERR.
May also be shown as 806f05132582ffff or 0x806f05132582ffff
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0234
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
Check the PCI LED.
2.
Reseat the affected adapters and riser card.
3.
Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
4.
Make sure that the adapter is supported. For a list of supported optional devices, see http://www.ibm.com/
systems/info/x86servers/serverproven/compat/us/.
5.
Remove both adapters.
6.
Replace the PCIe adapters.
7.
Replace the riser card.
806f052b-2101ffff
Invalid or Unsupported firmware or software was detected on system
[ComputerSystemElementName]. (IMM2 FW Failover)
Explanation:
This message is for the use case when an implementation has detected an Invalid/Unsupported
Firmware/Software Version.
May also be shown as 806f052b2101ffff or 0x806f052b2101ffff
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0446
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2.
Recover the server firmware from the backup page by restarting the server.
3.
Update the server firmware to the latest level (see Updating the firmware). Important: Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster solution before you update the code.
4.
Remove components one at a time, restarting the server each time, to see if the problem goes away.
5.
If the problem remains, (trained service technician) replace the system board.
806f0513-2582ffff • 806f052b-2101ffff
436
System x3100 M5 Type 5457: Installation and Service Guide
Содержание x3100 M5 Type 5457
Страница 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 679: ...Taiwan Class A compliance statement Notices 663 ...
Страница 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 687: ......
Страница 688: ... Part Number 00V9791 Printed in USA 1P P N 00V9791 ...