409-904-000
Nvidia::DiagnosticServiceProvider::Query Test Failed
Explanation:
Nvidia GPU Query Test Failed.
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system.
2.
Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3.
Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4.
Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of system issues
can cause diagnostic failure.
5.
If the problem remains, contact your IBM technical-support representative.
Related Links:
v
v
v
409-905-000
Nvidia::DiagnosticServiceProvider::Matrix Test Failed
Explanation:
Nvidia GPU Matrix Test Failed.
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system.
2.
Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3.
Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4.
Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of system issues
can cause diagnostic failure.
5.
If the problem remains, contact your IBM technical-support representative.
Related Links:
v
v
v
409-904-000 • 409-905-000
630
System x3100 M5 Type 5457: Installation and Service Guide
Содержание x3100 M5 Type 5457
Страница 1: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 8: ...vi System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 16: ...xiv System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 342: ...326 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 670: ...654 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 679: ...Taiwan Class A compliance statement Notices 663 ...
Страница 680: ...664 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 686: ...670 System x3100 M5 Type 5457 Installation and Service Guide ...
Страница 687: ......
Страница 688: ... Part Number 00V9791 Printed in USA 1P P N 00V9791 ...