806f0813-2584ffff
A Uncorrectable Bus Error has occurred on system [ComputerSystemElementName]. (CPUs)
Explanation:
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132584ffff or 0x806f08132584ffff
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0240
SNMP Trap ID:
50
Automatically notify Support:
Yes
User response:
1.
Check the system-event log.
2.
(Trained technician only) Remove the failing microprocessor from the system board (see Removing a
microprocessor and heat sink).
3.
Check for a server firmware update. Important: Some cluster solutions require specific code levels or coordinated
code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the
cluster solution before you update the code.
4.
Make sure that the two microprocessors are matching.
5.
(Trained technician only) Replace the system board.
806f0823-2101ffff
Watchdog Timer interrupt occurred for [WatchdogElementName]. (IPMI Watchdog)
Explanation:
This message is for the use case when an implementation has detected a Watchdog Timer interrupt
occurred.
May also be shown as 806f08232101ffff or 0x806f08232101ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0376
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
806f090c-2001ffff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 1)
Explanation:
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2001ffff or 0x806f090c2001ffff
Severity:
Warning
Alert Category:
System - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0142
SNMP Trap ID:
22
Automatically notify Support:
No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f0813-2584ffff • 806f090c-2001ffff
604
System x3650 M5 Type 5462: Installation and Service Guide
Содержание System x3650 M5
Страница 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1001: ...Taiwan Class A compliance statement Notices 985 ...
Страница 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1009: ......
Страница 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...