806f000d-041effff
The Drive [StorageVolumeElementName] has been added. (Drive 30)
Explanation:
This message is for the use case when an implementation has detected a Drive has been Added.
May also be shown as 806f000d041effff or 0x806f000d041effff
Severity:
Info
Alert Category:
Critical - Hard Disk drive
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0162
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
No action; information only.
806f000d-041fffff
The Drive [StorageVolumeElementName] has been added. (Drive 31)
Explanation:
This message is for the use case when an implementation has detected a Drive has been Added.
May also be shown as 806f000d041fffff or 0x806f000d041fffff
Severity:
Info
Alert Category:
Critical - Hard Disk drive
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0162
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
No action; information only.
806f000f-220101ff
The System [ComputerSystemElementName] has detected no memory in the system. (ABR
Status)
Explanation:
This message is for the use case when an implementation has detected that memory was detected in
the system.
May also be shown as 806f000f220101ff or 0x806f000f220101ff
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0794
SNMP Trap ID:
41
Automatically notify Support:
No
User response:
1.
Make sure that one or more DIMMs are installed in the server, and resolve any other currently existing memory
errors.
2.
If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that all DIMM
connectors are enabled using the Setup utility or the Advanced Settings Utility (ASU).
3.
Re-Install all DIMMs verifying the correct population sequence, according to the service information for this
product.
4.
Replace DIMMs.
5.
Recover the server firmware from the backup page: a. Restart the server. b. At the prompt, press F3 to recover
the firmware. c. Update the server firmware on the primary page. Important: Some cluster solutions require
806f000d-041effff • 806f000f-220101ff
Appendix A. Integrated management module II (IMM2) error messages
431
Содержание System x3650 M5
Страница 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1001: ...Taiwan Class A compliance statement Notices 985 ...
Страница 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1009: ......
Страница 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...