22.
If these recovery efforts fail, contact your IBM service representative for
support.
Results
In-band automated boot recovery method
This section details the in-band automated boot recovery method.
About this task
Note:
Use this method if the BOARD LED on the light path diagnostics panel is lit
and there is a log entry or
Booting Backup Image
is displayed on the firmware
splash screen; otherwise, use the in-band manual recovery method.
Procedure
1.
Boot the server to an operating system that is supported by the firmware
update package that you downloaded.
2.
Perform the firmware update by following the instructions that are in the
firmware update package readme file.
3.
Restart the server.
4.
At the firmware splash screen, press F3 when prompted to restore to the
primary bank. The server boots from the primary bank.
Results
Out-of-band method
See the IMM2 documentation (
Integrated Management Module II User's Guide
) at
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5086346.
Automated boot recovery (ABR)
Use this information for Automated boot recovery (ABR).
About this task
While the server is starting, if the integrated management module II detects
problems with the server firmware in the primary bank, the server automatically
switches to the backup firmware bank and gives you the opportunity to recover
the firmware in the primary bank. For instructions for recovering the UEFI
firmware, see “Recovering the server firmware (UEFI update failure)” on page 117.
After you have recovered the firmware in the primary bank, complete the
following steps:
Procedure
1.
Restart the server.
2.
When the prompt
Press F3 to restore to primary
is displayed, press F3 to
start the server from the primary bank.
Chapter 3. Troubleshooting
119
Содержание System x3650 M5
Страница 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1001: ...Taiwan Class A compliance statement Notices 985 ...
Страница 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1009: ......
Страница 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...