806f050c-2581ffff
Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (All DIMMS)
Explanation:
This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
May also be shown as 806f050c2581ffff or 0x806f050c2581ffff
Severity:
Warning
Alert Category:
Warning - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0144
SNMP Trap ID:
43
Automatically notify Support:
Yes
User response:
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different
memory channel or microprocessor.
3.
If the error still occurs on the same DIMM, replace the affected DIMM.
4.
If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any
foreign material or is damaged, replace the system board.
5.
(Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any
damaged pins. If a damage is found, replace the system board.
6.
(Trained technician only) Replace the affected microprocessor.
806f050d-0400ffff
Array [ComputerSystemElementName] is in critical condition. (Drive 0)
Explanation:
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0400ffff or 0x806f050d0400ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0174
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a lit status LED.
806f050c-2581ffff • 806f050d-0400ffff
Appendix A. Integrated management module II (IMM2) error messages
547
Содержание System x3650 M5
Страница 1: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 8: ...vi System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 16: ...xiv System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 58: ...42 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 86: ...70 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 320: ...304 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 832: ...816 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 988: ...972 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 992: ...976 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1001: ...Taiwan Class A compliance statement Notices 985 ...
Страница 1002: ...986 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1008: ...992 System x3650 M5 Type 5462 Installation and Service Guide ...
Страница 1009: ......
Страница 1010: ... Part Number 00AK781 Printed in USA 1P P N 00AK781 ...