Diagnostics
19
For example:
Controller 1 Slot 5, Status:Not responding properly - Error Code=0B0
Controller 2 Slot 4, Logical Drive=0, Other=0, Firmware=2.88.10, Status=Ok
Controller 3 Slot 3, Logical Drive=0, Other=0, Firmware=3.60.13, Status=Ok
Controller 4 Slot 2, Logical Drive=1, Other=1, Firmware=1.00.09, Status=Ok
If no errors occur:
ISPR (aaaa) = EF10
BCS (bb) = 0F or 09
ECS (cc) = 00
If an error occurs, refer to: “ServeRAID POST (ISPR) error codes” on page 232 for the
ISPR error codes and “Basic and Extended Configuration Status Register Codes” for
the BCS and ECS error codes.
Basic and Extended Configuration Status Register Codes:
BCS
ECS
Explanation and possible recovery action
Code not in
table
Code not in
table
Explanation:
The ServeRAID controller is not functioning properly.
Action:
Replace the adapter or the I/O board with integrated controller.
00
01
Explanation:
Invalid flash configuration.
Action:
Start the IBM ServeRAID Support CD and follow the instructions that appear
on the screen.
00
02
Explanation:
Invalid NVRAM configuration.
Action:
Start the IBM ServeRAID Support CD and follow the instructions that appear
on the screen.
00
03
Explanation:
Invalid flash and NVRAM configuration.
Action:
Start the IBM ServeRAID Support CD and follow the instructions that appear
on the screen.
01
08
Explanation:
No configuration was found in drives, or online/rebuild drives are not
responding.
Action:
Press F4, F5, F7, or F10.
01
18
Explanation:
No configuration was found in drives, or online/rebuild and hot-
spare/standby hot-spare drives are not responding.
Action:
Press F4, F5, F7, or F10.
01
28
Explanation:
No configuration was found in drives, or online/rebuild and
ready/standby drives are not responding.
Action:
Press F4, F5, F7, or F10.
01
38
Explanation:
No configuration was found in drives, or online/rebuild, hot-
spare/standby hot-spare, and ready/standby drives are not responding.
Action:
Press F4, F5, F7, or F10.
01
48
Explanation:
No configuration was found in drives, or online/rebuild drives are not
responding and unidentified drives were found.
Action:
Press F4, F5, F7, or F10.
Содержание 86655RY - Netfinity 7600 - 8665
Страница 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 271: ...Related service information 261 ...
Страница 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 273: ...Related service information 263 ...
Страница 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 285: ...Related service information 275 ...
Страница 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 293: ......