Symptom-to-FRU index
233
2.
Flash the controller with the latest IBM ServeRAID BIOS/Firmware from the IBM
Website.
3.
Remove the jumpers.
4.
If the error persists, replace ServeRAID controller.
6XXX
(Cache DRAM Error)
1.
Reseat Cache Memory SIMM.
2.
Install two download jumpers parallel to the PCI slots. For jumper locations, see
“Processor board component locations” on page 55.
3.
Flash the controller with the latest IBM ServeRAID BIOS/Firmware from the IBM
Website.
4.
Remove the jumpers.
5.
If the error persists, replace ServeRAID controller.
7XXX thru 8XXX
(Host/Local PCI Bus Interface Error)
1.
Install two download jumpers parallel to the PCI slots. For jumper locations,
“Processor board component locations” on page 55.
2.
Flash the controller with the latest IBM ServeRAID BIOS/Firmware from the IBM
Website.
3.
Remove the jumpers.
4.
If the error persists, replace ServeRAID controller.
9XXX thru BXXX
(SCSI bus error caused either by defective drives, termination, etc.)
1.
Isolate between SCSI subsystem and controller by disconnecting all SCSI cables
from suspect card, and reboot.
CAUTION:
Do not press F5. Doing so changes the customer’s configuration.
If an ISPR error is still present, perform the following actions until the error is no
longer present:
a.
Reseat the controller.
b.
Replace the controller.
Notes:
a. The controller detects a configuration change. Do not choose Save Changes.
Instead, press F10 to bypass any options to this effect.
2.
If ISPR error is EF10 after disconnecting cables:
a.
Identify which channel is causing the error by the second digit of the original
ISPR code:
ISPR = B1xx = Channel 1
ISPR = B2xx = Channel 2
ISPR = B3xx = Channel 1 and 2
ISPR = B4xx = Channel 3
ISPR = B5xx = Channel 1 and 3
ISPR = B6xx = Channel 2 and 3
ISPR = B7xx = Channel 1, 2 and 3
ISPR = BFxx = Channel not identified
b.
Confirm that the channel(s) identified from the error in step 2 is (are) the
cause of the error by verifying that the error presents itself ONLY when the
offending channel is reconnected.
c.
Check termination of identified channel.
d. Check for proper backplane jumper configuration.
e.
Check for proper cabling configuration in systems that use DASD status
cables. Reconnect all cables removed in step 1 above.
Содержание 86655RY - Netfinity 7600 - 8665
Страница 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 271: ...Related service information 261 ...
Страница 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 273: ...Related service information 263 ...
Страница 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 285: ...Related service information 275 ...
Страница 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 293: ......