236
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
SCSI error codes
Temperature error messages
Bxxx (SCSI bus interface error)
1.
Refer to “ServeRAID POST (ISPR) error procedures” on
page 232.
2.
SCSI cable
3.
SCSI backplane
4.
Hard drive
5.
ServeRAID 3HB Adapter/Controller
Error Code
FRU/Action
All SCSI Errors
One or more of the following might be
causing the problem:
•
A failing SCSI device (adapter, drive, controller)
•
An improper SCSI configuration or SCSI termination
jumper setting
•
Duplicate SCSI IDs in the same SCSI chain
•
A missing or improperly installed SCSI terminator
•
A defective SCSI terminator
•
An improperly installed cable
•
A defective cable
1.
External SCSI devices must be powered-on before
you power-on the server.
2.
The cables for all external SCSI devices are
connected correctly.
3.
If you have attached an external SCSI device to the
server, make sure the external SCSI termination is
set to automatic.
4.
The last device in each SCSI chain is terminated
correctly.
5.
The SCSI devices are configured correctly.
Message
Action
DASD "X" Over Temperature
(level-critical; Direct
Access Storage Device bay "X" was over temperature)
1.
Ensure system is being properly cooled
; see
“Temperature checkout” on page 31.
DASD Over recommended Temperature
(sensor X)
(level-warning; the DASD backplane had an over
temperature condition)
1.
Ensure system is being properly cooled
; see
“Temperature checkout” on page 31.
DASD under recommended temperature
(sensor X)
level-warning; the DASD backplane had an under
temperature condition)
1.
Ambient temperature must be within normal operating
specifications
; (see “Features and specifications” on page
3).
Power Supply "X" Temperature Fault
(level-critical;
power supply "x" had over temperature condition)
1.
Ensure system is being properly cooled;
see
“Temperature checkout” on page 31.
2.
Replace Power Supply "X"
System board is over recommended temperature
(level-warning; system board is over recommended
temperature)
1.
Ensure system is being properly cooled;
see
“Temperature checkout” on page 31.
2.
Replace system board
System board is under recommended temperature
(level-warning; system board is under recommended
temperature)
1.
Ambient temperature must be within normal operating
specifications
; (see “Features and specifications” on page
3).
Error Code/Symptom
Action
Содержание 86655RY - Netfinity 7600 - 8665
Страница 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 271: ...Related service information 261 ...
Страница 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 273: ...Related service information 263 ...
Страница 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 285: ...Related service information 275 ...
Страница 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Страница 293: ......