Error Code/Symptom
FRU/Action
020-XXX-004
(Failed Hot-Swap Slot 4 PCI
Latch test)
1. PCI Hot-Swap Latch
Assembly
2. System Board
030-XXX-000
(Failed Internal SCSI
interface test)
1. System Board
035-XXX-000
DUPLICATE ERROR CODE
(Failed System Board RAID
test. Check System Error
Log before replacing a
FRU.)
1. Verify RAID adapter
disable jumper block
is not installed (see
“System board
jumpers” on
page 257).
2. System Board
3. SCSI Backplane
4. Cable
035-XXX-000
DUPLICATE ERROR CODE
(Check System Error Log
before replacing a FRU.)
1. Fixed Disk with SCSI
ID 00 on System
Board RAID
controller
035-XXX-0NN
(Check System Error Log
before replacing a FRU.
NN = SCSI ID of failing
fixed disk.)
1. Fixed Disk with SCSI
ID NN on System
Board RAID
controller
035-XXX-100
DUPLICATE ERROR CODE
(Failed RAID test on PCI
slot 1. Check System Error
Log before replacing a
FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-100
DUPLICATE ERROR CODE
(Check System Error Log
before replacing a FRU.)
1. Fixed Disk with SCSI
ID 00 on RAID
adapter in PCI slot 1
035-XXX-1NN
(Check System Error Log
before replacing a FRU.
NN = SCSI ID of failing
fixed disk.)
1. Fixed Disk with SCSI
ID NN on RAID
adapter in PCI slot 1
035-XXX-200
DUPLICATE ERROR CODE
(Failed RAID test on PCI
slot 2. Check System Error
Log before replacing a
FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-200
DUPLICATE ERROR CODE
(Check System Error Log
before replacing a FRU.)
1. Fixed Disk with SCSI
ID 00 on RAID
adapter in PCI slot 2
035-XXX-2NN
(Check System Error Log
before replacing a FRU.
NN = SCSI ID of failing
fixed disk.)
1. Fixed Disk with SCSI
ID NN on RAID
adapter in PCI slot 2
Netfinity 5500 - Type 8660
271
Содержание 866011U - Netfinity 5500 - 8660
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 201: ...a Remove the information panel LED assembly screws then remove the assembly Netfinity 5500 Type 8660 193...
Страница 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Страница 231: ...a Remove the power backplane screws 1 then remove the power backplane Netfinity 5500 Type 8660 223...
Страница 244: ...Screws 236 Netfinity Server HMM...
Страница 247: ...Netfinity 5500 Type 8660 239...
Страница 269: ...a Remove the system board mounting screws then remove the system board Netfinity 5500 Type 8660 261...
Страница 301: ...Parts listing Type 8660 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Netfinity 5500 Type 8660 293...
Страница 314: ...306 Netfinity Server HMM...
Страница 324: ...316 Netfinity Server HMM...
Страница 325: ...Related service information 317...
Страница 326: ...318 Netfinity Server HMM...
Страница 327: ...Related service information 319...
Страница 340: ...332 Netfinity Server HMM...
Страница 341: ...Related service information 333...
Страница 346: ...338 Netfinity Server HMM...
Страница 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...