next array to RDY. Then, return to step 3 to create
the next array. If you have finished creating the
arrays, continue with step 6 on page 104.
6. When the initialization process completes, you have
completed the required steps for creating a
ServeRAID disk-array configuration.
7. Back up the disk-array configuration information to
diskette. See “Backing up the disk-array
configuration” on page 126 for instructions.
8. You are now ready to install the operating system.
Refer to the information provided in the ServerGuide
package.
Creating disk arrays manually:
You can use the
Create/Delete/Copy Log Drive menu to create the disk
arrays manually. You also can use this menu to define the
logical and hot-spare drives for the arrays. You must
define at least one logical drive for each array.
To create a disk array manually:
1. Start the ServeRAID Configuration program (see
“Starting the ServeRAID Configuration program” on
page 77).
2. Select Create/Delete/Copy Log Drive from the Main
Menu; then, press Enter.
A screen similar to the following appears.
Bay
Array
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ch
2
INI
RDY
CDR
RDY
RDY
RDY
Select a choice using the Up Arrow ( ) and Down Arrow ( ) keys and press Enter.
Press Esc to return to previous menu.
Main Menu
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX
Adapter Number: 1
Bus Number: 0 Host ID = Null Config
Bay
Array
Ch
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
INI
RDY
RDY
RDY
1. Help
2. Delete Disk Array
3. Create Disk Array
4. Define Logical Drive
5. Copy Logical Drive
6. Define/Undefine Hot-spare Drive
7. Delete Logical Drive
8. Exit
Create/Delete/Copy Log Drive
3. Select Create Disk Array; then, press Enter.
4. Use the Up Arrow (
↑
) or Down Arrow (
↓
) key to
highlight each drive that you want to include in the
array; then, press Enter. The cursor is active in the
Array/Bay selection list. (You must press Enter to
select each drive. As you select each drive, the state
of that drive changes from ready (RDY) to online
(ONL).)
104
Netfinity Server HMM
Содержание 866011U - Netfinity 5500 - 8660
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 201: ...a Remove the information panel LED assembly screws then remove the assembly Netfinity 5500 Type 8660 193...
Страница 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Страница 231: ...a Remove the power backplane screws 1 then remove the power backplane Netfinity 5500 Type 8660 223...
Страница 244: ...Screws 236 Netfinity Server HMM...
Страница 247: ...Netfinity 5500 Type 8660 239...
Страница 269: ...a Remove the system board mounting screws then remove the system board Netfinity 5500 Type 8660 261...
Страница 301: ...Parts listing Type 8660 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Netfinity 5500 Type 8660 293...
Страница 314: ...306 Netfinity Server HMM...
Страница 324: ...316 Netfinity Server HMM...
Страница 325: ...Related service information 317...
Страница 326: ...318 Netfinity Server HMM...
Страница 327: ...Related service information 319...
Страница 340: ...332 Netfinity Server HMM...
Страница 341: ...Related service information 333...
Страница 346: ...338 Netfinity Server HMM...
Страница 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...