logical drive that is in the okay (OKY) state. During the
LDM procedure, the ServeRAID controller changes the
state of the FRE logical drive to SYS; then, temporarily
uses the SYS drive to perform the migration. When the
migration procedure completes, the ServeRAID controller
changes the state of the SYS drive back to FRE.
Changing RAID levels:
To use the Change RAID Level feature, all of the logical
drives within the array must be the same RAID level.
The ServeRAID controller supports changing RAID levels
as follows:
Change two RAID level 0 logical drives to RAID level 5
by adding one hard disk drive
Change two RAID level 1 logical drives to RAID level 5
by adding one hard disk drive
Change from RAID level 5 to RAID level 0 by
removing one hard disk drive
To change the RAID level:
1. Click on the
icon on the tool bar or select
Manage Disk Arrays from the Advanced pull-down
menu; then, select Logical Drive Migration.
A screen similar to the following appears.
Logical Drive Migration
Logical Drive Migration Options
Change RAID Level
Add Physical Drive(s)
OK
Cancel
2. Select Change RAID Level; then, click on OK.
You can change (migrate) the RAID levels of
currently defined logical drives. Depending
upon the current RAID level, you might need
to add or remove a hard disk drive before you
can change the RAID level.
Netfinity 5500 - Type 8660
39
Содержание 866011U - Netfinity 5500 - 8660
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 201: ...a Remove the information panel LED assembly screws then remove the assembly Netfinity 5500 Type 8660 193...
Страница 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Страница 231: ...a Remove the power backplane screws 1 then remove the power backplane Netfinity 5500 Type 8660 223...
Страница 244: ...Screws 236 Netfinity Server HMM...
Страница 247: ...Netfinity 5500 Type 8660 239...
Страница 269: ...a Remove the system board mounting screws then remove the system board Netfinity 5500 Type 8660 261...
Страница 301: ...Parts listing Type 8660 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Netfinity 5500 Type 8660 293...
Страница 314: ...306 Netfinity Server HMM...
Страница 324: ...316 Netfinity Server HMM...
Страница 325: ...Related service information 317...
Страница 326: ...318 Netfinity Server HMM...
Страница 327: ...Related service information 319...
Страница 340: ...332 Netfinity Server HMM...
Страница 341: ...Related service information 333...
Страница 346: ...338 Netfinity Server HMM...
Страница 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...