Attention
When you select Yes in the Confirm pop-up
window, information in the target logical drive will
be overwritten with information from the source
logical drive. All existing data on the target
logical drive is lost.
6. Select Yes to copy the logical drive; then, press
Enter.
Bay
Array
Bay
Array
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ch
1
Ch
2
INI
RDY
CDR
B
B
HSP
ONL
ONL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
INI
Copy operation will destroy data on target logical drive.
Confirm start.
Main Menu
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX
Adapter Number: 1
Bus Number: 0 Host ID = Null Config
A
A
ONL
ONL
A
ONL
1. Help
Create/Delete/Copy Log Drive
Source
0
1
2
3
4
5
6
7
Target
1
Confirm
1. No
2. Yes
Array
ID Size
Log
Drv
Size
(MB)
RAID
Level
Status
Pct
R/W
A0
B0
100
100
RAID-5
RAID-1
OKY
OKY
A
B
3009
4126
The copy progress appears in the percent Read/Write
(Pct. R/W) column as a percentage of the total
number of sectors read and written.
7. When the copy process completes, back up the
disk-array configuration information to diskette. See
“Backing up the disk-array configuration” on page 126
for instructions.
Copying an existing disk array:
You can use the
following instructions to create a complete copy (including
the RAID configuration information) of an existing array.
You can use this procedure to duplicate the current
disk-array configuration for use on another system.
To copy an existing disk array:
1. Back up the configuration of the source system to a
diskette. (See “Backing up the disk-array
configuration” on page 126.)
2. On the source system, create a copy of the disk array
that you want to use on another system.
For example, if you want a copy of Array A to use on
another system, create an Array B that is identical to
Array A. (See “Creating disk arrays manually” on
page 104.)
3. Copy all logical drives from the source array to the
target array.
For example, if you made an identical copy of Array A
and that copy is Array B, you would copy all logical
Netfinity 5500 - Type 8660
123
Содержание 866011U - Netfinity 5500 - 8660
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 201: ...a Remove the information panel LED assembly screws then remove the assembly Netfinity 5500 Type 8660 193...
Страница 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Страница 231: ...a Remove the power backplane screws 1 then remove the power backplane Netfinity 5500 Type 8660 223...
Страница 244: ...Screws 236 Netfinity Server HMM...
Страница 247: ...Netfinity 5500 Type 8660 239...
Страница 269: ...a Remove the system board mounting screws then remove the system board Netfinity 5500 Type 8660 261...
Страница 301: ...Parts listing Type 8660 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Netfinity 5500 Type 8660 293...
Страница 314: ...306 Netfinity Server HMM...
Страница 324: ...316 Netfinity Server HMM...
Страница 325: ...Related service information 317...
Страница 326: ...318 Netfinity Server HMM...
Страница 327: ...Related service information 319...
Страница 340: ...332 Netfinity Server HMM...
Страница 341: ...Related service information 333...
Страница 346: ...338 Netfinity Server HMM...
Страница 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...