Hard Event displays the number of SCSI I/O
processor events that occurred on the drive
since the Device Event Log was last cleared. It
also indicates if the drive exceeded the
Predictive Failure Analysis (PFA) threshold.
Notes
1. If a PFA event is detected, it appears
beside the hard event information.
2. If the drive exceeded the PFA
threshold, back up the RAID level 0
logical drives. Then, replace the drive.
Parity Event displays the number of parity
events that occurred on the SCSI bus since the
Device Event Log was last cleared.
Misc Event displays the number of other events
(such as selection timeout, unexpected bus free,
or SCSI phase event) that occurred on the drive
since the Device Event Log was last cleared.
5. Press Esc to return to the Main Menu.
Viewing or changing the ServeRAID controller
parameters:
You can use the ServeRAID Configuration
program to view or change the ServeRAID controller
parameters.
To view or change the ServeRAID controller
parameters:
1. Start the ServeRAID Configuration program (see
“Starting the ServeRAID Configuration program” on
page 77).
2. Select Advanced Functions from the Main Menu;
then, press Enter.
3. Select Display/Change Adapter Params from the
next menu; then, press Enter.
A screen similar to the following appears.
Bay
Array
Bay
Array
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ch
1
Ch
2
INI
RDY
CDR
B
B
HSP
ONL
ONL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
INI
IBM ServeRAID Adapter Disk Array Configuration Ver. X.XX
Adapter Number: 1
Bus Number: 0 Host ID = Null Config
A
A
ONL
ONL
A
ONL
1. Help
2. Display Adapter Status
3. Change Adapter Host/SCSI ID
4. Set BIOS Compatability Mapping
5. Set Channel -> Bank Mapping
6. Exit
Display/Change Adapter Parameter
Select drive using the Up Arrow ( ) and Down Arrow ( ) keys.
Press Esc to return to the previous menu.
Descriptions of the choices available from this menu
are as follows:
Netfinity 5500 - Type 8660
115
Содержание 866011U - Netfinity 5500 - 8660
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 201: ...a Remove the information panel LED assembly screws then remove the assembly Netfinity 5500 Type 8660 193...
Страница 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Страница 231: ...a Remove the power backplane screws 1 then remove the power backplane Netfinity 5500 Type 8660 223...
Страница 244: ...Screws 236 Netfinity Server HMM...
Страница 247: ...Netfinity 5500 Type 8660 239...
Страница 269: ...a Remove the system board mounting screws then remove the system board Netfinity 5500 Type 8660 261...
Страница 301: ...Parts listing Type 8660 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Netfinity 5500 Type 8660 293...
Страница 314: ...306 Netfinity Server HMM...
Страница 324: ...316 Netfinity Server HMM...
Страница 325: ...Related service information 317...
Страница 326: ...318 Netfinity Server HMM...
Страница 327: ...Related service information 319...
Страница 340: ...332 Netfinity Server HMM...
Страница 341: ...Related service information 333...
Страница 346: ...338 Netfinity Server HMM...
Страница 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...