Using the Advanced Configuration
functions
The Advanced Functions choice allows you to initialize the
configuration (reset the ServeRAID controller settings),
import the configuration information from the drives, enable
and disable the Boot CD-ROM and INT13 extensions, and
view the controller and PCI information.
When you select Advanced Functions from the Main Menu,
a screen similar to the following appears.
Select a choice using the Up and Down Arrow keys, then press Enter.
IBM ServeRAID Adapter Disk Array Mini-Configuration Ver. X.XX
Advanced Functions
Initialize Configuration
Import Configuration from Drive(s)
Configure BIOS Settings
Adapter and PCI Information
Exit
Descriptions of the choices available from the Advanced
Functions menu are as follows:
Attention
The following choices might result in loss of data
due to changes in the configuration.
Initialize Configuration resets the ServeRAID
controller settings to their factory defaults and sets all
functional hard disk drives to the RDY state.
Import Configuration from Drive(s) reads the most
common configuration information from the drives in
the server and copies it to the controller’s NVRAM
and to the controller’s EEPROM module.
Boot CD-ROM and INT13 Extensions is used to
configure the BootCd feature. When BootCd is
enabled, the ServeRAID controller attempts to start
(boot) from a CD, if the CD-ROM drive contains a
startable (boot-enabled) CD, and no other controller is
currently using INT13 extensions.
Attention:
Only one controller can support INT13 extensions.
Adapter and PCI Information displays the
ServeRAID controller hardware and PCI register
information, as shown in the following example
screen.
Netfinity 5500 - Type 8660
89
Содержание 866011U - Netfinity 5500 - 8660
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 201: ...a Remove the information panel LED assembly screws then remove the assembly Netfinity 5500 Type 8660 193...
Страница 214: ...1 Hard disk drive 2 Drive tray handle open position 206 Netfinity Server HMM...
Страница 231: ...a Remove the power backplane screws 1 then remove the power backplane Netfinity 5500 Type 8660 223...
Страница 244: ...Screws 236 Netfinity Server HMM...
Страница 247: ...Netfinity 5500 Type 8660 239...
Страница 269: ...a Remove the system board mounting screws then remove the system board Netfinity 5500 Type 8660 261...
Страница 301: ...Parts listing Type 8660 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Netfinity 5500 Type 8660 293...
Страница 314: ...306 Netfinity Server HMM...
Страница 324: ...316 Netfinity Server HMM...
Страница 325: ...Related service information 317...
Страница 326: ...318 Netfinity Server HMM...
Страница 327: ...Related service information 319...
Страница 340: ...332 Netfinity Server HMM...
Страница 341: ...Related service information 333...
Страница 346: ...338 Netfinity Server HMM...
Страница 402: ...IBM Part Number 00N5902 Printed in U S A S1 L 98 3...