Table 33 shows the offline and online tests.
Attention:
Offline diagnostic tests are disruptive to switch operation.
Table 33. Offline and online diagnostic tests
Offline tests
Offline and online tests
camTest
crossPortTest
centralMemoryTest
ramTest
cmemRetentionTest
cmiTest
portLoopbackTest
portRegTest
spinSilk
sramRetentionTest
camTest
Figure 46 shows the camTest command that verifies that the SID translation
required by QuickLoop and implemented using content addressable memories
(CAM) is functioning correctly.
Attention:
This command is not performed on an operational switch. Before
issuing the camTest command, disable the switch by using the switchDisable
command. Disabling the switch halts all operation on the switch.
Related error messages: DIAG-CAMINIT, DIAG-CAMSID, DIAG-XMIT.
centralMemoryTest
Figure 47 on page 103 shows the centralMemoryTest command, which is used to
check the central memory in each ASIC as follows:
v
The built-in-self-repair (BISR) circuit in each ASIC chip does not report a failure
to repair bad cells (bisr test).
v
The data cells are uniquely written into and then read correctly (data write/read
test).
v
The data in any one ASIC can be read from any other ASIC (asic-asic test_).
v
Bad parity is detected and flagged in the error register and an interrupt is posted
(parity error test).
v
Buffer number errors can be detected and flagged in the error register and an
interrupt is posted (buffer number error test).
v
Chip number errors are detected and flagged in the error register and an
interrupt is posted (chip number error test).
Attention:
This command cannot be performed on an operational switch. Before
issuing the centralMemoryTest command, disable the switch, using the
switchDisable command.
switch:admin> camTest
Running CAM Test .............. passed.
Figure 46. camTest command example
102
IBM SAN Fibre Channel Switch: 2109 Model S16 Installation and Service Guide
Содержание 2109 - SAN Fibre Channel Switch Model S16
Страница 2: ......
Страница 3: ...IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide SC26 7352 01 IBM...
Страница 12: ...x IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 14: ...xii IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 34: ...18 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 60: ...44 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 84: ...68 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 100: ...84 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 102: ...Figure 33 A fabric with three zones 86 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 106: ...90 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 132: ...116 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 146: ...130 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 154: ...138 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 160: ...144 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 172: ...156 IBM SAN Fibre Channel Switch 2109 Model S16 Installation and Service Guide...
Страница 177: ......