SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
- 114 -
Encoder Control
Configure Encoder settings.
Note:
Descriptions of each command can also be found in "
" (Setting List).
Encoder Control Name
Access
Short
ASCII
Values
Default
Value
Example / Description
EncoderSourceA
R/W
ENCSA
0: Line5 Opt In1
1: Line4 TTL In1
2: Line10 TTL In2
3: Line13 TTL In3
0
ENCSA=[Param.]<CR><LF>
ENCSA?<CR><LF>
Select where to input the signal from the
rotary encoder.
EncoderSourceB
R/W
ENCSB
0: Line5 Opt In1
1: Line4 TTL In1
2: Line10 TTL In2
3: Line13 TTL In3
0
ENCSB=[Param.]<CR><LF>
ENCSB?<CR><LF>
Select where to input the signal from the
rotary encoder.
EncoderDivider
R/W
ENCDIV 1 ~ 4294967295
65536
ENCDIV=[Param.]<CR><LF>
ENCDIV?<CR><LF>
Set the number of triggers to be
generated during one pitch of the rotary
encoder. The number of triggers is
65536 / (set value).
EncoderFilter
R/W
ENFIL
0 ~ 15 (cycle)
Note:
10ns/cycle
0
ENFIL=[Param.]<CR><LF>
ENFIL?<CR><LF>
Apply a low-pass filter to prevent noise
on the signal from the rotary encoder
and stabilize the signal for the specified
number of cycles.
EncoderStrobe
R/W
ENSTR 1 ~ 256 (1 = 10ns)
1
ENSTR=[Param.]<CR><LF>
ENSTR?<CR><LF>
Set the strobe length of the Trigger
signal generated from the rotary
encoder by the number of cycles.
EncoderAveragingInterval
R/W
ENAVE
0: none
1: 2 pulses
2: 4 pulses
3: 8 pulses
4: 16 pulses
5: 32 pulses
0
ENAVE=[Param.]<CR><LF>
ENAVE?<CR><LF>
Perform the internal processing by
averaging the time interval of the
specified number of signals.