SW-4000T-MCL User Manual (2.0)
Setting List
- 75 -
PulseGenerator
Configure pulse generator settings.
Pulse Generator Item
Setting Range
Default Value
Description
ClockPreScaler
1 ~ 4096
1
Set the division value for the prescaler (12 bit)
using PixelClock as the base clock.
PulseGeneratorClock (MHz)
0.0244 ~ 100
-
Set the clock used for the pulse generator. This
value is calculated using the ClockPreScaler value
as a base.
PulseGeneratorClock = 100 / ClockPreScaler
PulseGeneratorSelector
0:PulseGenerator0
1:PulseGenerator1
2:PulseGenerator2
3:PulseGenerator3
0:PulseGenerator0 Select the pulse generator.
PulseGeneratorLength
1 ~ 1048575
30000
Set the maximum count-up value as a clock count.
PulseGeneratorLength (ms)
1/
PulseGeneratorClock
(MHz) to 1048575/
PulseGeneratorClock
(MHz)
66.6667
Set the maximum count-up value in milliseconds.
This value is calculated using the
PulseGeneratorLength value as a base. The
setting range varies depending on the
ClockPreScaler value.
PulseGeneratorLengthMs =
1/PulseGeneratorClock * PulseGeneratorLength
PulseGeneratorFrequency
(Hz)
0 ~ 1048575
15
Set the maximum count-up value as a frequency
(Hz).
This value is calculated using the
PulseGeneratorLength value as a base.
PulseGeneratorFrequency = 1sec /
PulseGeneratorLengthMs
PulseGeneratorStartPoint
0 ~ 1048575
0
Set the start point of the High interval as a clock
count. When the counter reaches this value, the
output will be 1.
PulseGeneratorStartPoint
(ms)
0 to (1048575 /
PulseGeneratorClock
(MHz))
0
Set the start point of the High interval in
milliseconds. When the counter reaches this
value, the output will be 1. The setting range varies
depending on the ClockPreScaler value.
PulseGeneratorStartPointMs =
1/PulseGeneratorClock *
PulseGeneratorStartPoint
PulseGeneratorEndPoint
1 ~ 1048575
15000
Set the start point of the Low interval as a clock
count. When the counter reaches this value, the
output will be 0.