SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
- 90 -
Analog Control
Name
Access
Short
ASCII
Values
Default
Value
Example / Description
GainInt[DigitalBlue]
R/W
GAB
IndividualGainMode = Off:
40 ~ 400
IndividualGainMode = On:
100 ~ 1600
100
GAB=[Param.]<CR><LF>
GAB?<CR><LF>
Set Gain[DigitalBlue]. The setting range varies
depending on the IndividualGainMode setting.
AnalogBaseGain
[AnalogGreen]
R/W
SGG
0:0dB
1:6dB
2:12dB
0
SGG=[Param.]<CR><LF>
SGG?<CR><LF>
Set AnalogBaseGain[AnalogGreen].
AnalogBaseGain
[AnalogRed]
R/W
SGR
0:0dB
1:6dB
2:12dB
0
SGR=[Param.]<CR><LF>
SGR?<CR><LF>
Set AnalogBaseGain[AnalogRed].
AnalogBaseGain
[AnalogBlue]
R/W
SGB
0:0dB
1:6dB
2:12dB
0
SGB=[Param.]<CR><LF>
SGB?<CR><LF>
Set AnalogBaseGain[AnalogBlue].
BalanceWhiteAuto
R/W
AWB
0:Off (Default)
2:Once
4:Exposure Once
5:Preset 5000K
6:Preset 6500K
7:Preset 7500K
0
AWB=[Param.]<CR><LF>
AWB?<CR><LF>
Set BalanceWhiteAuto. When set to
Once
, the
automatic adjustment will be performed only
once, and then automatically switched to Off.
Note:
When set to
IndividualGainMode
,
only
Off
can be selected.
AWBAreaWidth
R/W
AWBW
Min / Step: 16(8)*
Max: 4096 (2048)* -
AWBOffsetX
Note:
*When
BinningHorizontal = 2 ,
the value in parentheses
is applicable.
-
AWBW=[Param.]<CR><LF>
AWBW?<CR><LF>
Specify the width of the referenced area when
BalanceWhiteAuto
is set to
Once
,
AWBAreaOffsetX
R/W
AWBO
Min: 0
Max: 4096 (2048)* -
AWBWidth
Step: 16(8)*
Note:
*When
BinningHorizontal = 2 ,
the value in parentheses
is applicable.
0
AWBO=[Param.]<CR><LF>
AWBO?<CR><LF>
Specify the offset of the referenced area when
BalanceWhiteAuto
is set to
Once
,