SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
- 89 -
Acquisition Control
Name
Access
Short
ASCII
Values
Default
Value
Example / Description
RBExposureInterlocked
R/W
EI
0:Off
1:On
0
EI=[Param.]<CR><LF>
EI?<CR><LF>
Adjust exposure time of the R and B channels
automatically in conjunction with exposure time
of the G channel.
ExposureTimeMin
R
PEMIN
-
-
PEMIN?<CR><LF>
Display the minimum exposure time.
ExposureTimMax
R
PEMAX
-
-
PEMAX?<CR><LF>
Display the maximum exposure time.
AcquisitionLineRateOption
R/W
LROP
0: mode1
1: mode2
1
LROP=[Param.]<CR><LF>
LROP?<CR><LF>
Set the AcquisitionLineRateOption. If mode2 is
selected, the maximum line rate is limited.
Analog Control
Configure the analog control setting.
Note:
Descriptions of each command can also be found in "
" (Setting List).
Analog Control
Name
Access
Short
ASCII
Values
Default
Value
Example / Description
IndividualGainMode
R/W
GM
0:Off
1:On
0
GM=[Param.]<CR><LF>
GM?<CR><LF>
Configure Gain individually when set to On.
GainInt[DigitalAll]
R/W
GA
100 ~ 800
-
GA=[Param.]<CR><LF>
GA?<CR><LF>
Set Gain [DigitalAll], when IndividualGainMode
is Off.
GainInt[DigitalRed]
R/W
GAR
IndividualGainMode = Off:
40 ~ 400
IndividualGainMode = On:
100 ~ 1600
-
GAR=[Param.]<CR><LF>
GAR?<CR><LF>
Set Gain[DigitalRed]. The setting range varies
depending on the IndividualGainMode setting.
GainInt[DigitalGreen]
R/W
GAG
IndividualGainMode = Off:
40 ~ 400
IndividualGainMode = On:
100 ~ 1600
100
GAG=[Param.]<CR><LF>
GAG?<CR><LF>
Set Gain[DigitalGreen].
Содержание SW-4000T-MCL
Страница 119: ...SW 4000T MCL User Manual 2 0 Miscellaneous 119 Spectral Response...
Страница 120: ...SW 4000T MCL User Manual 2 0 Miscellaneous 120 Dimensions F Mount Notes l Dimensional Tolerance 0 3mm l Unit mm...
Страница 121: ...SW 4000T MCL User Manual 2 0 Miscellaneous 121 Dimensions M52 Mount Notes l Dimensional Tolerance 0 3mm l Unit mm...