Pulse Generator Name
Access
Short
ASCII
Values
Default
Value
Example / Description
PulseGeneratorStartPoint
[PulseGenerator1]
R/W
PGST1 0 ~ 1048575
0
PGST1=[Param.]<CR><LF>
PGST1?<CR><LF>
Set the start point of the High
interval as a clock count for
PulseGenerator1. When the
counter reaches this value, the
output will be 1.
PulseGeneratorStartPoint
[PulseGenerator2]
R/W
PGST2 0 ~ 1048575
0
PGST2=[Param.]<CR><LF>
PGST2?<CR><LF>
Set the start point of the High
interval as a clock count for
PulseGenerator2. When the
counter reaches this value, the
output will be 1.
PulseGeneratorStartPoint
[PulseGenerator3]
R/W
PGST3 0 ~ 1048575
0
PGST3=[Param.]<CR><LF>
PGST3?<CR><LF>
Set the start point of the High
interval as a clock count for
PulseGenerator3. When the
counter reaches this value, the
output will be 1.
PulseGeneratorEndPoint
[PulseGenerator0]
R/W
PGEN0 0 ~ 1048575
0
PGEN0=[Param.]<CR><LF>
PGEN0?<CR><LF>
Set the start point of the Low
interval as a clock count for
PulseGenerator0. When the
counter reaches this value, the
output will be 0.
PulseGeneratorEndPoint
[PulseGenerator1]
R/W
PGEN1 0 ~ 1048575
0
PGEN1=[Param.]<CR><LF>
PGEN1?<CR><LF>
Set the start point of the Low
interval as a clock count for
PulseGenerator1. When the
counter reaches this value, the
output will be 0.
PulseGeneratorEndPoint
[PulseGenerator2]
R/W
PGEN2 0 ~ 1048575
0
PGEN2=[Param.]<CR><LF>
PGEN2?<CR><LF>
Set the start point of the Low
interval as a clock count for
PulseGenerator2. When the
counter reaches this value, the
output will be 0.