SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
- 111 -
Correction Control Name
Access
Short
ASCII
Values
Default
Value
Example / Description
FIRFilterRightRatioInt [Red]
R/W
FFRRR -200 ~ 200
0
FFRRR=[Param.]<CR><LF>
FFRRR?<CR><LF>
Set the coefficient of the right pixel when
FIR Filter for Red is applied.
FIRFilterRightRatioI [Green]
R/W
FFRRG -200 ~ 200
0
FFRRG=[Param.]<CR><LF>
FFRRG?<CR><LF>
Set the coefficient of the right pixel when
FIR Filter for Green is applied.
FIRFilterRightRatio [Blue]
R/W
FFRRB -200 ~ 200
0
FFRRB=[Param.]<CR><LF>
FFRRB?<CR><LF>
Set the coefficient of the right pixel when
FIR Filter for Blue is applied.
MEDIANFilterMode [Red]
R/W
MFR
0: Off
1: On
0
MFR=[Param.]<CR><LF>
MFR?<CR><LF>
Enable / Disable MEDIAN Filter for Red.
MEDIANFilterMode [Green]
R/W
MFG
0: Off
1: On
0
MFG=[Param.]<CR><LF>
MFG?<CR><LF>
Enable / Disable MEDIAN Filter for
Green.
MEDIANFilterMode [Blue]
R/W
MFB
0: Off
1: On
0
MFB=[Param.]<CR><LF>
MFB?<CR><LF>
Enable / Disable MEDIAN Filter for Blue.
NoiseReduction
R/W
NR
0: Off
1: Level1
2: Level2
3: Level3
4: Level4
0
NR=[Param.]<CR><LF>
NR?<CR><LF>
Set the noise reduction intensity in 4
levels. Level1 = weak, Level4 = strong.