CounterAndTimerControl
Configure counter settings.
Note:
This camera only supports the counter functions.
Related Topic:
Counter and Timer Control Function
CounterAndTimer
Control Item
Setting
Range
Default
Value
Description
CounterSelector
0 ~ 3:
Counter0 ~ 3
0: Counter0
Select the counter.
CounterEventSource
-
0: Off
Assign the Counter Event signal for which you want to read the
count value to a dedicated counter and read the value.
0: Off
1: Line Trigger (Counter0 only)
2: Exposure Start (Counter2 only)
3: Line Start (Counter1 only)
4: Line Transfer End (Counter3 only)
CounterEventActivation
0:Rising
Edge
-
Display the count timing. The setting value is fixed to Rising Edge.
CounterReset
-
-
Reset the counter.
Note:
Available only when
CounterResetSource
is set to
Software
.
CounterRefresh
-
-
Update the counter.
CounterValue
-
-
Display the count value.
CounterStatus
-
0:
CounterIdle
Display the counter status.
0: CounterIdle
2: CounterActive
4: CounterOverflow - Count value exceeded the maximum value.