![IAI SW-4000T-MCL Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/iai/sw-4000t-mcl/sw-4000t-mcl_user-manual_4466064106.webp)
SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
- 106 -
Pulse Generator Name
Access
Short
ASCII
Values
Default
Value
Example / Description
PulseGeneratorClearSource
[PulseGenerator2]
R/W
PGIN2
Same as PGIN0
Note:
12:
PulseGenerator2 cannot
be selected.
0
PGIN2=[Param.]<CR><LF>
PGIN2?<CR><LF>
Select the count clear input
signal source for
PulseGenerator2.
PulseGeneratorClearSource
[PulseGenerator3]
R/W
PGIN3
Same as PGIN0
Note:
13:
PulseGenerator3 cannot
be selected.
0
PGIN3=[Param.]<CR><LF>
PGIN3?<CR><LF>
Select the count clear input
signal source for
PulseGenerator3.
PulseGeneratorClearInverter
[PulseGenerator0]
R/W
PGINV0
0:False
1:True
0
PGINV0=[Param.]<CR><LF>
PGINV0?<CR><LF>
Controls if the pulse generator
clear signal is inverted. False
means "Active High" and True
for "Active Low".
PulseGeneratorClearInverter
[PulseGenerator1]
R/W
PGINV1
0:False
1:True
0
PGINV1=[Param.]<CR><LF>
PGINV1?<CR><LF>
Controls if the pulse generator
clear signal is inverted. False
means "Active High" and True
for "Active Low".
PulseGeneratorClearInverter
[PulseGenerator2]
R/W
PGINV2
0:False
1:True
0
PGINV2=[Param.]<CR><LF>
PGINV2?<CR><LF>
Controls if the pulse generator
clear signal is inverted. False
means "Active High" and True
for "Active Low".
PulseGeneratorClearInverter
[PulseGenerator3]
R/W
PGINV3
0:False
1:True
0
PGINV3=[Param.]<CR><LF>
PGINV3?<CR><LF>
Controls if the pulse generator
clear signal is inverted. False
means "Active High" and True
for "Active Low".
PulseGeneratorClearSyncMode
[PulseGenerator0]
R/W
PGSM0
0:Async Mode
1:Sync Mode
0
PGSM0=[Param.]<CR><LF>
PGSM0?<CR><LF>
Selects the sync mode of the
input to clear PulseGenerator0.
Содержание SW-4000T-MCL