SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
- 91 -
Analog Control
Name
Access
Short
ASCII
Values
Default
Value
Example / Description
AWBExposureOnce
Status
R
AHRS
1=Succeeded.
2=Error1 - G image was too
bright.
3=Error2 - G image was too
dark.
4=Error3 - Timeout-error
occurred.
5=IDEL
-
AWHS?<CR><LF>
Displays the status at the time of execution
(BalanceWhiteAuto=ExposureOnce).
AWBOnceStatus
R
AWRS
1=Succeeded.
2=Error1 - G image was too
bright.
3=Error2 - G image was too
dark.
4=Error3 - Timeout-error
occurred.
5=IDEL
-
AWBS?<CR><LF>
Display the status when
BalanceWhiteAuto
is
set to
Once
,
BlackLevel
[DigitalAll]
R/W
BL
-133 ~ 255
0
BL=[Param.]<CR><LF>
BL?<CR><LF>
Controls the analog black level as an absolute
physical value. This represents a DC offset
applied to the video signal.
BlackLevel
[DigitalRed]
R/W
BLR
-64 ~ 64
0
BLR=[Param.]<CR><LF>
BLR?<CR><LF>
Set BlackLevel[Red].
BlackLevel
[DigitalBlue]
R/W
BLB
-64 ~ 64
0
BLB=[Param.]<CR><LF>
BLB?<CR><LF>
Set BlackLevel[Blue].
GainAuto
R/W
AGC
0:Off
1:Once
0
AGC=[Param.]<CR><LF>
AGC?<CR><LF>
Enable/disable gain auto adjustment. Once
automatically changes to Off when the signal
level converges once.
AGCReference
R/W
AGCR
30 ~ 95
Unit: %
50
AGCF=[Param.]<CR><LF>
AGCF?<CR><LF>
Set the target level for AGC.
AGCOnceStatus
R
AGCS
1: Succeeded.
2: Error1 - Timeout-error
occurred.
3: Abort1 - Contro lLimit
4: Idle
4
AGCS?<CR><LF>
Display the status when GainAuto is set to
Once.