SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
- 105 -
Pulse Generator Name
Access
Short
ASCII
Values
Default
Value
Example / Description
PulseGeneratorClearActivation
[PulseGenerator1]
R/W
PGCM1
0: Off
1: Level High
2: Level Low
4: Rising Edge
8: Falling Edge
0
PGCM1 =[Param.]<CR><LF>
PGCM1 ?<CR><LF>
Set the clear signal condition for
the count clear input of
PulseGenerator1.
PulseGeneratorClearActivation
[PulseGenerator2]
R/W
PGCM2
0: Off
1: Level High
2: Level Low
4: Rising Edge
8: Falling Edge
0
PGCM2 =[Param.]<CR><LF>
PGCM2 ?<CR><LF>
Set the clear signal condition for
the count clear input of
PulseGenerator2.
PulseGeneratorClearActivation
[PulseGenerator3]
R/W
PGCM3
0: Off
1: Level High
2: Level Low
4: Rising Edge
8: Falling Edge
0
PGCM3 =[Param.]<CR><LF>
PGCM3 ?<CR><LF>
Set the clear signal condition for
the count clear input of
PulseGenerator3.
PulseGeneratorClearSource
[PulseGenerator0]
R/W
PGIN0
0: Low
1: High
7: ExposureActive
9: LVAL
10-13: PulseGenerator0-3
14-17: UserOutput0-3
20: Line4: TTL In1
21: Line5: Opt In1
23: Line7 - CC1
24: Line10: TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13: TTL In3
29: EncoderTriger
30: EncoderDirection
Note:
10:
PulseGenerator0 cannot
be selected.
0
PGIN0=[Param.]<CR><LF>
PGIN0?<CR><LF>
Select the count clear input
signal source for
PulseGenerator0.
PulseGeneratorClearSource
[PulseGenerator1]
R/W
PGIN1
Same as PGIN0
Note:
11:
PulseGenerator1 cannot
be selected.
0
PGIN1=[Param.]<CR><LF>
PGIN1?<CR><LF>
Select the count clear input
signal source for
PulseGenerator1.
Содержание SW-4000T-MCL
Страница 119: ...SW 4000T MCL User Manual 2 0 Miscellaneous 119 Spectral Response...
Страница 120: ...SW 4000T MCL User Manual 2 0 Miscellaneous 120 Dimensions F Mount Notes l Dimensional Tolerance 0 3mm l Unit mm...
Страница 121: ...SW 4000T MCL User Manual 2 0 Miscellaneous 121 Dimensions M52 Mount Notes l Dimensional Tolerance 0 3mm l Unit mm...