Str
ongArmPark DC: Lighting Connection
1.
Make sur
e both AC and DC power switches ar
e turned OFF
.
2.
Insert leads of wir
e harness thr
ough the hole in chassis between
the two bracket mounts. Feed the cable thr
ough the interior of
the chassis. Pull enough cable to r
each the Smart DC Contr
oller
terminals.
NOTE:
Connect wir
e lead (female quick connect) l24V to 24VDC.
Lights will be dim if lead is connected to 12VDC terminal.
3.
Attach the end of the wir
e harness (on the outside of the
chassis) to the LED light connector on the arm. The wir
e harness
connector is keyed. Be sur
e to seat the connectors befor
e
thr
eading close. See illustration on pr
evious page.
4.
Make sur
e the harness is secur
ed to the chassis with the strain
relief bushing. See illustration on pr
evious page.
+24V
DC Power
Switch
AC Power
Switch
LED Arm light connector
Wir
e harness
connector
Connect Arm Light Cables
Turn OFF AC and DC power
Shown separated
for r
efer
ence only
W
ire ties
Factory installed magnet
(kill switch)
End cap
Knob
Br
eakaway
fasteners
Connections to Contr
oller
Female Quick Connects:
User2 Relay (NO) & +24VDC
Spade connections:
COM & SENSOR 3
Spline collar
bolt & nut
Exploded V
iew
Smart DC Contr
oller: Menu Mode Navigation Buttons
To access
Menu mode
To change menu item
appearing in the display
To navigate thr
ough
the menu item selections
Pr
ess the Menu button
twice.
Pr
ess Select.
Two left characters blink.
Pr
ess Next or Pr
evious.
Continue pr
essing Next to view all
selections.
To choose what item appears
on the display
To navigate between
menu items
Pr
ess Select.
Blinking characters
become static.
Pr
ess Next or Pr
evious.
Advance - pr
ess Next
Pr
evious - pr
ess Pr
evious
5.
Connect female quick connect l24V to the
24VDC
power supply terminal. See wiring illustrations.
6.
Connect the second female quick connect to the NO terminal on
User Relay 2.
NOTE:
If you ar
e planning to pr
ogram the pr
oximity sensor in the br
eakaway
bracket assembly
, connect one spade connection to COM and the other to
SENSOR 3 (Photo Eye Close on BY1 operators).
Spade
connections
82
MX3650-01 Rev. D
StrongArmPark DC Programming & Operations
© 2017
www.hysecurity.com