Table 4: Installer Menu
Installer Menu
Setting Options
Menu Tasks & Explanations
SDC Wire
Connections
SG 0 (OFF)
Sequenced Gate
0 = off
1 = Loop Layout/Site #1
2 = Loop Layout/Site #2
Establishes communication after wiring two or
more operators as sequenced gates.
This menu item only appears if the Dual Gate
menu item DG is set at 0 (solo operator).
NOTE:
Access the User Menu in both
operators and set a Close Timer.
Connect Dual Gate
COM (Traffic Gate)
to
Dual Gate COM
(Security Gate)
A to A
B to B
CH 0 (AC)
Charger Type
0 = AC powered charger
1 = Solar powered charger
Assigns charger type.
If a solar-powered unit is ordered and delivered
factory-ready, this menu will not appear.
NOTE:
Menu item does not appear on an AC-
powered operator.
BT 0 (STANDARD)
Battery Type
0 = standard 8Ah
1 = extended (50 Ah)
2 = maximum (110 Ah)
Assign the battery type used by the operator.
Smaller batteries are charged with less current
to avoid overheating and larger batteries are
charged with more current to supply a more
rapid charge.
Extended and
maximum batteries
require separate
housing and wiring.
FO 0 (OFF)
Fire Dept Open
0 = disabled
1 = enabled
Provides the Fire Dept. Open input and allows
a button to activate the emergency open when
connected to +24VDC. When set to 1, the
open signal received by the operator overrides
all photoelectric eyes and edge sensors, and
opens the barrier arm. Pressing the Reset or
Open button is required before the barrier arm
can be closed.
+24V
Fire Dept Open
SE 0
IES Sensitivity
0 = Maximum (highest) sensitivity
1 = Moderate sensitivity
2 = Least sensitivity
Adjusts the sensitivity of the dynamic reversing
sensor. Available settings are 0 to 2. Zero is the
default and reacts quickly (high sensitivity) to
impediments.
NOTE:
For StrongArmPark DC, adjust the
spring to prevent false trips prior to changing
the sensitivity.
See NOTE.
LC 0 (0.0 SECS)
Leaf Delay Close
0 = none
1 through 20
For example:
1 = ½ second
4 = 2 seconds
20 = 10 seconds
Delays gate closure. This menu option appears
if the gate operator is designated as a dual
gate system (Master/Second, for example).
Available settings are 1 to 20. Each increment
adds
½ second, to a maximum of 10 seconds
time delay, before the operator activates
when commanded to close.
DUAL GATE inputs
on both operators
LO 0 (0.0 SECS)
Leaf Delay Open
0 = none
1 through 20
For example:
1 = ½ second
4 = 2 seconds
20 = 10 seconds
Delays gate opening. This menu option
appears if the gate operator is designated
as a dual gate system (Master/Second, for
example). Available settings are 1 to 20. Each
increment adds
½ second (with a maximum of
10 seconds) time delay following a command
to open before the operator activates.
DUAL GATE inputs
on both operators
EC 0 STOP ONLY
Eye Close Logic
0 = Close eye stops only
1 = Reverse to full open with barrier
gates (2 second reverse to open on
swing, slide, or vertical gates)
The default setting is non-reversal if the close
photo eye is triggered. A setting of 1 causes
the barrier arm to reverse and travel full open if
triggered while closing.
EYE Close
EYE COM
(Inputs #14 or #15)
26
MX3650-01 Rev. D
StrongArmPark DC Programming & Operations
© 2017
www.hysecurity.com