![HySecurity StrongArmPark DC Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/hysecurity/strongarmpark-dc/strongarmpark-dc_programming-and-operations-manual_2194152087.webp)
CAUTION
Wires are attached
to the physical stop
bracket. Do NOT sever
the wires or hang the
bracket by the wires.
12
3
Using a ½-inch socket wrench, remove four
fasteners securing the physical stop bracket.
(Do NOT break the wire connections.) Hang the
bracket from the side of the chassis, as shown.
12
4
Remove the drive belt. Use a
>\zn
-inch socket
wrench to loosen (do NOT remove) the 4 bolts
securing the motor to the motor plate.
12
2
If the drive belt cover is in place, use a phillips
head screwdriver to remove two screws that
secure it to the motor plate. Set the drive belt
cover and fasteners aside.
CAUTION
12
5
Wires are attached
to the motor!
• Disconnect the 2 motor
wire leads from the
wire harness inside the
chassis.
• Disconnect the blue
connector wire from the
Smart DC Controller
and pull it out of the
control box.
12
1
Remove the front access panel. (Keys come with
the operator.)
Use a phillips head screwdriver to remove the
plastic cover from the control box.
12
6
Top cover
Drive belt cover
Drive belt
Loosen, DO NOT remove, 4 bolts
on motor cover plate
Physical stop bracket
Two phillips head screws
Control box:
Smart DC
Controller
access
Set screws
Nylon bolts for
breakaway bracket
Motor.
See
CAUTION
ContInued
....
Turn the page for more information.
Disconnect the
2 motor wires.
Disconnect wire
leads before
removing the motor
Remove 4 bolts and lift the motor plate
assembly from the chassis. Set it aside.
Physical stop bracket
Reference
H
andIng
C
Hange
All StrongArmPark DC operators are shipped from the factory in a left handing configuration unless specified
otherwise. If you need to change the StrongArmPark DC14 handing at the site, you will need to:
• Release spring tension
• Swap locations of the spring’s eyebolt
and spacer on the physical stop lever
• Retention the spring
NOTE:
If changing the handing on StrongArmPark DC10,
follow steps 1 and 10.
www.hysecurity.com
© 2017
Reference
MX3650-01 Rev. D
77