Table 7: Programmable User Relays, Revenue Control Parking Applications
Relay No.
Name
Description
Wire Connection
31
Device Reset Pulse Output
N.O. Input. A 250ms pulse occurs when the Center
Loop is triggered. If a back out occurs, this relay
sends a reset pulse to the access control device or
computer system to invalidate the ticket.
R1, R3 through R10
32
Back Out Pulse Output
N.O. Input. The relay outputs a 250ms pulse when a
back out has occurred based on the criteria given in
the “Revenue Control Parking Functions.”
R1, R3 through R10
33
Inbound Transient/Lot Output
N.O. Input. The relay outputs a 250ms pulse used to
increment the transient and total vehicle counts.
R1, R3 through R10
TRANSIENT USER
34
Outbound Transient/Lot Output
N.O. Input. The relay outputs a 250ms pulse used to
decrement the transient and total vehicle counts.
R1, R3 through R10
TRANSIENT USER
35
Inbound Tenant Output
N.O. Input. The relay outputs a 250ms pulse and
increments the tenant counter when the Tenant User
input is activated and OALD, then CLD, are tripped
and released. This activity signals a prepaid customer
has entered the facility.
R1, R3 through R10
TENANT USER
36
Outbound Tenant Output
N.O. Input. The relay outputs a 250ms pulse and
decrements the tenant counter when the Tenant
User input is activated and IALD, then CLD, are
tripped and released. This activity signals a prepaid
customer has exited the facility.
R1, R3 through R10
TENANT USER
37
Inbound Special Output
N.O. Input. The relay outputs a 250ms pulse and
increments the special counter when the SPECIAL
USER input is activated and OALD, then CLD, are
tripped and released. This activity signals a customer
has entered the facility.
R1, R3 through R10
SPECIAL USER
38
Outbound Special Output
N.O. Input. The relay outputs a 250ms pulse and
decrements the tenant counter when the SPECIAL
USER input is activated and IALD, then CLD, are
tripped and released. This activity signals a customer
has exited the facility.
R1, R3 through
R10SPECIAL USER
39
Set aside for Factory Use
HySecurity Testing Only
Do not use
e
xtended
r
elaY
m
odule
o
ptIon
The extended relay module provides 8 numbered mechanical relays. R3,
RELAY 3 LOGIC through R10, RELAY 10 LOGIC can be accessed through
the Installer Menu. Set the number for the relay based on the information
found in Tables 4 or 5. Table 5 is oriented toward revenue control parking
lot applications.
Wire communication cable connections between the DUAL GATE ports,
at the base of the SDC, and the extended-mechanical relay module. See
illustration
Overview of the Smart DC Controller on page 34
.
42
MX3650-01 Rev. D
StrongArmPark DC Programming & Operations
© 2017
www.hysecurity.com