Table 3: User Menu
User Menu
Setting Options
Menu Tasks & Explanations
SDC Wire Connections
US 0
CLEAR COUNT
0 = preprogrammed limit
1 = Clear Transient count
2 = Clear Tenant count
3 = Clear Special count
4 = All User
Clears the logs (counts) of “user types” entering
or exiting through the StrongArmPark DC gate.
This menu is used most often in Parking lot and
revenue control scenarios. Selecting a number and
pressing SELECT again, clears the count.
COM
TRANSIENT USER
TENANT USER
SPECIAL USER
DS 0 (OFF)
Diagnostic Logs
0 = off
1 = detailed
Set to 0, the SDC logs pertinent operator events
such as faults, errors, or menu manipulation. When
experiencing intermittent problems, set this item
to 1 to record all operator open and close events,
in addition to the normal alert, fault and error logs.
This parameter automatically resets to the default
0 (off) after 24 hours.
USB or RS-232 cable
and laptop computer
loaded with HySecurity
free S.T.A.R.T. software
is required to read the
log file.
Visit www.hysecurity.com
PD 0
Set Password
0 = Off
1 = On, Set Password
To enter a password (up to 80 characters) for
network connectivity, select 1. You can use the
menu navigation buttons to enter the password
(SELECT, NEXT, SELECT). When the password is
set, the display returns to the 0 setting.
NOTE:
A System Address (SA) value in the Installer
Menu must be set before the Set Password display
can appear in the User Menu.
Network: Ethernet or
RS-485
I
nstaller
m
enu
The Installer Menu options provide more advanced configurations for
the gate operators. Access to the Installer Menu is through the User
Menu. The navigational buttons are the same in both menu modes.
Access:
While a static Run Mode code is being displayed, press the MENU
button twice. (Bypasses the operator status displays.)
When the Close Timer display appears:
1.
Access the Installer Menu
by simultaneously pressing and
holding the RESET and OPEN buttons.
2. Release both buttons and the Learn Limit display appears. The
LL display is the first item in the Installer Menu.
NOTE:
Installer Menu options can also be configured through the use of a
laptop computer and the S.T.A.R.T. software.
Table 4 describes the Installer Menu items and supplies the factory defaults. (Factory settings shown in bold.)
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
24
MX3650-01 Rev. D
StrongArmPark DC Programming & Operations