![HySecurity StrongArmPark DC Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/hysecurity/strongarmpark-dc/strongarmpark-dc_programming-and-operations-manual_2194152062.webp)
SECURE
PUBLIC
CENTER LOOP
INNER ARMING LOOP
OUTER ARMING LOOP
(OALD)
FREE EXIT LOOP
(optional)
A
B
C
E
F
D
PEDESTRIAN GA
TE & WALKWA
Y
C
(IALD)
Drawings not to scale.
*NOTICE
For sequenced gates to operate
properly, all vehicle detectors
must be wired to the Traffic
Control Gate
.
If a communication failure occurs,
an AL22 (Alert 22) appears and the
buzzer sounds. The Traffic Control
Gate maintains functionality
whilethe Security Gate defaults
to open until communication is
restored (or the Security Gate is
manually closed).
**NOTICE
Center to center between gates:
4 ft minimum (122 cm)
9 ft maximum (274 cm)
Uni- or Bi-directional Traffic Control
Vehicles must pass from one loop to
the next without loss of detection.
Dimension “A” = 6 ft minimum to 12 ft
maximum (183 to 366 cm).
Dimension “B” = 2 ft minimum to 3 ft
maximum (61 to 91 cm).
Dimension “C” = 3 ft min. to 4 ft max.
Distance from edge of Center Loop to
C/L of the Security Gate is 3 to 4 ft.
Dimension “D” = 6 ft (183 cm).
Dimension “E” =
4 ft min. to 8 ft (122 to
244 cm)
max. Center Loop can be offset
from C/L of gate: 1 to 5 ft (31 to 152 cm).
Dimension “F” = 10 to 15 feet (3 to 3.6 m)
Optional access control
devices (card reader, etc.).
Align along 6 ft edge of the
Outside Obstruction Loop.
Location changes depending on
uni- or bi-directional traffic.
To sequence the gates, set the
Installer Menu item, SG to “2” in
both gate operators.*
2
Operator & Loops**
As traffic control and security gates
are separated farther apart, Center
Loop moves toward centering under
the Traffic Control Gate.
(OOLD for Security Gate)
Loop can be offset from
C/L of barrier arm 1 to 5 ft
(31 to 152 cm)
(IOLD for Security Gate)
SECURITY SLIDE GATE
TRAFFIC CONTROL GATE
IALD for Traffic Control Gate or
Free Exit for both operators. If
loop used as Free Exit, you must
have an OALD loop.
Minimum 2 ft (61 cm)
StrongArmPark DC (Traffic Control Gate)
with SlideSmart DC (Security Gate)
SECURITY SLIDE GATE
Minimum 2 ft (61 cm)
s
equenCed
g
ates
#2: l
oop
l
aYout
StrongArmPark DC Loop Layout
52
MX3650-01 Rev. D
StrongArmPark DC Programming & Operations
© 2017