background image

Operator Mounting

Wall Mount:

 The operator should generally be installed below 

the door shaft, and as close to the door as possible.

Bracket Shelf Mounting:

 The operator may be mounted either 

above or below the door shaft.

NOTE:

 The optimum distance between the door shaft and 

operator drive shaft is between 12" - 15".

Place door sprocket on the door shaft. 

Do not insert the key at 

this time.

Place drive sprocket on the appropriate side of the operator. 

Do 

not insert the key or set screw at this time.

Wrap chain drive around door sprocket and join roller chain 
ends together with master link.

Raise operator to approximate mounting position and position 
chain over operator sprocket.

Raise or lower operator until the chain is taut (not tight). Make 
sure the operator output shaft is parallel to door shaft and 
sprockets are aligned. When in position, secure the operator to 
wall or mounting bracket.

Align sprockets, insert key into keyway, and secure.

Place hand chain around hand chain wheel (if provided).

Run the power wires through the power wiring conduit hole in 
the electrical box enclosure. Connect the power to the operator. 
Connect the earth ground to the ground screw in the electrical 
box enclosure. 

Follow ALL local electrical codes.

Run control wires through the control wiring conduit hole in the 
electrical box enclosure. 

Follow ALL local electrical codes.

Adjust the limit switches to open and close door properly. Make 
sure the limit nuts are positioned between the limit switches 
before proceeding with adjustments.

Remove cotter pin from nut on the clutch shaft. Back off clutch 
nut until there is very little tension on the clutch spring. Tighten 
clutch nut gradually until there is just enough tension to permit 
the operator to move the door smoothly but to allow the clutch 
to slip if the door is obstructed. Reinstall cotter pin when 
finished.

Troubleshooting instructions inside cover of operator.

1b

1a

2

3

4

5

6

7

8

9

10

11

12

13

IMPORTANT:  This QuickStart is intended to highlight a typical installation. These instructions are not intended to be comprehensive. Because each application is unique, it is the responsibility of 
the purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use. Please consult the manual and/or a qualified technician for further information.
NOTE: Intended for Professional Installation Only. Visit www.LiftMaster.com to locate a professional installing dealer in your area.

A SAFETY DEVICE IS HIGHLY RECOMMENDED

Align Sprockets

7

OPTIONAL

Mounting Bracket
P/N 08-9098

Be sure door sprocket is properly
aligned with drive before securing to
the shaft.

Chain Retaining Bracket
(4' above floor)

Optimum Distance

12-15"

Optimum Distance

12-15"

Right Hand Wall Mounted Operator

1a

Bracket Shelf Mounted Operator

1b

MODEL MH

These operators are equipped with a manual hoist. An electrical interlock will disable the 
electrical controls when the hoist is used. To operate the hoist. 

Turn off power to the operator 

BEFORE manually operating your door.

 

 

 

      Pull the disconnect chain (sash chain) to engage the hoist mechanism. The disconnect 
      chain may be locked in position by slipping the end through the keyhole of the chain       
       retaining bracket mounted on the wall.

      Operate the door in the desired direction by pulling on one side or the other of the
 

continuous loop hoist chain.

      The disconnect chain must be released from the chain retaining bracket before the door   
      will operate again electrically.

MODEL MJ

This operator has a floor level disconnect chain to disconnect the door from the door 
operator.

       To disengage, pull the chain and secure in the disengaged position by slipping the end
       through the keyhole bracket mounted on the wall. Or if emergency egress device is used, 
      pull handle to disengage operator from door.

       The door may now be pushed up or pulled down manually. 

 

Release the disconnect chain or reset the emergency egress device to operate the 

 

door again electronically.

MODEL MHS

This operator includes two methods of manual operation:

 

A disconnect sash chain for push-up/pull-down operation. Refer to Model MJ 

 instructions 

above.

 

A hoist engagement sash chain for manual hoist operation. This chain can be found on the 

 

clutch side of the operator. Refer to Model MH instructions above.

When operator is disconnected by the manual operation chain, hoist and electrical operation 
will not function.

Manual Operation

QuickStart

 

model MJ/MH/MHS

Medium Duty Logic

Keyhole Bracket

Manual Disconnect

Electrical Interlock with Hoist

a

a

b

c

a

b

c

b

Turn off power to the operator

BEFORE

 manually operating your door.

b

a