background image

For more information, please visit www.devancocanada.com or call toll free at 855-931-3334

Model# CPT-210 Sensing Edge

Assembly Instructions

Components List:

CPT210-K-5

50 ft. - CPT223 extrusion

5 - Wired End Plugs

5 - Non- Terminated End Plugs or Terminated with 8.2k/10k/DC

1 - Tube Vyna Bond Glue

Step 1: Cut the Extrusion

1- Measure the width of the door.

2- Cut the extrusion 1 inch less than the door width.

Note: Ensure that the cut be square and free of rubber fragments.

Step 2: Insert the Blank End Plug and Glue.

1- Insert 50% of the blank or terminated  end plug into the extrusion. 

2- Apply a continuous bead of Vyna Bond glue ONLY around the perimeter. 

3- Fully insert plug and hold firmly to fully seat the plug and form an 

airtight seal. 

4- Use caution, do not allow glue to contact conductive tongue. 

Step 3: Insert the Wired End Plug and Glue.  

1- Insert 50% of the wired end plug into the extrusion. 

2- Apply a continuous bead of Vyna Bond ONLY around the perimeter.

3- Fully insert plug and hold firmly to fully seat the plug and form an

airtight seal. 

4- Use caution, do not allow glue to contact conductive tongue. 

Use Caution: 

Do NOT allow glue on

the conductive tongue.

IMPORTANT:

PLEASE ENSURE THAT THE FOLLOWING INSTRUCTIONS ARE FOLLOWED

CPT TECHNOLOGY - RESISTIVE SAFETY EDGES

P.O. Box 159 • West Grove, PA 19390 • (610)869-4422 • Fax: (610)869-4423 •  800-220-3343 

6809 South Harl Avenue, Suite A, Tempe, AZ 85283 • (480)755-3565 • Fax (480)755-3558 • 800-887-3343

www.milleredge.com

Отзывы: