Embedded Smart Array
The installed Smart Array firmware version. This value is displayed only if server POST has
successfully completed since the last auxiliary power cycle.
iLO IPv4
The iLO IPv4 address. This value is displayed only if
Show iLO IP during POST
is enabled on the
Access Settings
page.
iLO IPv6
The iLO IPv6 address. This value is displayed only if
Show iLO IP during POST
is enabled on the
Access Settings
page.
iLO Hostname
The iLO hostname.
Critical Log Entries
The most recent
Critical
events from the IML are displayed, with the most recent event displayed
first.
Front panel LED power fault codes
When a power fault occurs, the following front panel LEDs flash simultaneously:
• System power LED
• Health LED
• NIC LED
• UID LED
For more information about the LED locations on your server, see the server user guide in the
Packard Enterprise Information Library
.
The number of flashes in each sequence corresponds to the subsystem impacted by the power fault. The
following table provides a list of power fault codes, and the subsystems that are affected. Not all power
faults are used by all servers.
Subsystem
Front panel LED behavior
System board
1 flash
Processor
2 flashes
Memory
3 flashes
Riser board PCIe slots
4 flashes
FlexibleLOM
5 flashes
Removable HPE Flexible Smart Array controller/
Smart SAS HBA controller
6 flashes
System board PCIe slots
7 flashes
Power backplane or storage backplane
8 flashes
Power supply
9 flashes
30
Front panel LED power fault codes