For more information about installing memory, see the server user guide on the Hewlett Packard
Enterprise website (
http://www.hpe.com/info/proliantgen10-docs
Solution 4
Cause
Scalable Persistent Memory functionality is disabled because a physical NVDIMM is installed in the
server.
Action
Remove the physical NVDIMM from the server.
For more information about removing NVDIMMs from the server, see the server maintenance and service
guide on the Hewlett Packard Enterprise website (
http://www.hpe.com/info/proliantgen10-docs
The persistent memory drive is read only
Symptom
A persistent memory drive marked as "read only" usually indicates that the underlying NVDIMM detected
is not armed for backup during the boot process.
Solution 1
Cause
Previous backup operation failed.
Action
Check the IML for the cause of the backup failure and perform the recommended action.
Solution 2
Cause
The current restore operation failed.
Action
Check the IML for the cause of the restore failure and perform the recommended action.
Solution 3
Cause
A general Scalable Persistent NVDIMM arming error occurred.
The persistent memory drive is read only
111