Capacity Management Features
67
Produ
ct Des
c
ript
ion
controller with 256 Mbytes of cache will use half of the memory to mirror the other
controller, leaving only 128 Mbytes for its own cache.
The write cache contents cannot be flushed when both controllers are removed from the
disk array simultaneously. In this case the write cache image is lost and data integrity on
the disk array is compromised. To avoid this problem, never remove both controllers from
the disk array simultaneously.
In the event of an unexpected disk array shutdown or loss of power, the BBU provides
power to cache memory to maintain the cache for 120 hours (5 days).
Dynamic Capacity Expansion
If slots are available in the disk enclosures, you can increase the capacity of the disk array
without disrupting operation. By simply adding new disks to the array and then creating a
new LUN the capacity can be expanded. See
"Adding Capacity to the Disk Array" on
page 254
for more information on adding disks and other ways of increasing disk array
capacity.
Содержание Surestore Disk Array 12h - And FC60
Страница 16: ...16 ...
Страница 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Страница 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Страница 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Страница 68: ...68 Capacity Management Features ...
Страница 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Страница 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Страница 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Страница 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Страница 134: ...134 Topologies for Windows NT and Windows 2000 Figure 45 Four Host Single Hub Single Disk Array Non HA Topology ...
Страница 136: ...136 Topologies for Windows NT and Windows 2000 Figure 47 Four Host Single Switch Dual Disk Array Non HA Topology ...
Страница 138: ...138 Topologies for Windows NT and Windows 2000 Figure 48 Direct Connect Single Host Single Disk Array HA Topology ...
Страница 140: ...140 Topologies for Windows NT and Windows 2000 Figure 50 Four Host Dual Hub Dual Disk Array HA Topology ...
Страница 142: ...142 Topologies for Windows NT and Windows 2000 ...
Страница 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Страница 159: ...Installing the Disk Array FC60 159 Installation Figure 55 Enclosure EIA Positions for Legacy Cabinets ...
Страница 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Страница 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Страница 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Страница 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Страница 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Страница 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Страница 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Страница 358: ...358 Support Tools Manager ...
Страница 401: ...Controller Enclosure Modules 401 Removal and Replacement Figure 101 BBU Removal and Replacement ...
Страница 440: ...440 FCC Statements USA Only ...