Managing the Disk Array Using Array Manager 60
287
M
a
na
ging
the
Di
sk
Array
on HP-UX
Vendor ID = HP
Product ID = A5277A
Array ID = 000A00A0B80673A6
Array alias = Array1
-----------------------------------------
Overall State of Array = READY
Array configuration:
Cache Block Size = 4 KB / 4 KB
Cache Flush Threshold = 80 % / 80 %
Cache Flush Limit = 100 % / 100 %
Cache Size = 256MB / 256MB
Vendor ID = HP
Product ID = A5277A
Array ID = 000A00A0B80673A6
Array alias = Array1
-----------------------------------------
Array Controller Subsystem:
Controller A: GOOD
Controller B: GOOD
PS 1: GOOD
PS 2: GOOD
Fan 1: GOOD
Fan 2: GOOD
Temp Sensor: GOOD
Battery: GOOD
Disk System 1 - USSA02010592:
BCC Controller B: GOOD
BCC Controller A: GOOD
PS 1: GOOD
PS 2: GOOD
Fan 1: GOOD
Fan 2: GOOD
Temp Sensor: GOOD
Disk System 2 - USSA02010595:
BCC Controller B: GOOD
BCC Controller A: GOOD
PS 1: GOOD
PS 2: GOOD
Fan 1: GOOD
Fan 2: GOOD
Temp Sensor: GOOD
No LUNs are currently rebuilding
Component status - all hardware
components should be GOOD
Cache settings
Содержание Surestore Disk Array 12h - And FC60
Страница 16: ...16 ...
Страница 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Страница 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Страница 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Страница 68: ...68 Capacity Management Features ...
Страница 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Страница 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Страница 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Страница 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Страница 134: ...134 Topologies for Windows NT and Windows 2000 Figure 45 Four Host Single Hub Single Disk Array Non HA Topology ...
Страница 136: ...136 Topologies for Windows NT and Windows 2000 Figure 47 Four Host Single Switch Dual Disk Array Non HA Topology ...
Страница 138: ...138 Topologies for Windows NT and Windows 2000 Figure 48 Direct Connect Single Host Single Disk Array HA Topology ...
Страница 140: ...140 Topologies for Windows NT and Windows 2000 Figure 50 Four Host Dual Hub Dual Disk Array HA Topology ...
Страница 142: ...142 Topologies for Windows NT and Windows 2000 ...
Страница 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Страница 159: ...Installing the Disk Array FC60 159 Installation Figure 55 Enclosure EIA Positions for Legacy Cabinets ...
Страница 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Страница 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Страница 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Страница 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Страница 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Страница 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Страница 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Страница 358: ...358 Support Tools Manager ...
Страница 401: ...Controller Enclosure Modules 401 Removal and Replacement Figure 101 BBU Removal and Replacement ...
Страница 440: ...440 FCC Statements USA Only ...
Страница 466: ...466 Index ...