
Installing the Disk Enclosures
165
Inst
alla
tion
7. If using an HP rack, fasten the back of the disk enclosure to the rails using the rear
hold-down clamps from the rail kit.
a. If you are installing the disk enclosure in an HP legacy rack, set the clamp (A in
Figure 59
) on top of the rail (B) so that the tabs point up and the screw holes are on
the slotted side of the rail. Skip to step c.
b. If you are installing the disk enclosure in an HP Rack System/E, set the clamp (D in
Figure 57
)
c. Push the clamp tight against the back of the disk enclosure. The raised tab of the
clamp should overlap the bottom edge of the disk enclosure chassis.
d. Insert and tighten two M5 16mm screws through each clamp and rail.
Figure 59
Legacy Rack Rail Clamp Installation, Disk Enclosure
8. Reinstall power supplies removed in Step 1.
9. Install half-EIA unit rack filler panel(s) as needed. A half-EIA unit gap exists between
products in legacy HP racks and when an odd number of disk enclosures are installed
in the Rack System/E.
Содержание Surestore Disk Array 12h - And FC60
Страница 16: ...16 ...
Страница 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Страница 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Страница 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Страница 68: ...68 Capacity Management Features ...
Страница 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Страница 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Страница 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Страница 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Страница 134: ...134 Topologies for Windows NT and Windows 2000 Figure 45 Four Host Single Hub Single Disk Array Non HA Topology ...
Страница 136: ...136 Topologies for Windows NT and Windows 2000 Figure 47 Four Host Single Switch Dual Disk Array Non HA Topology ...
Страница 138: ...138 Topologies for Windows NT and Windows 2000 Figure 48 Direct Connect Single Host Single Disk Array HA Topology ...
Страница 140: ...140 Topologies for Windows NT and Windows 2000 Figure 50 Four Host Dual Hub Dual Disk Array HA Topology ...
Страница 142: ...142 Topologies for Windows NT and Windows 2000 ...
Страница 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Страница 159: ...Installing the Disk Array FC60 159 Installation Figure 55 Enclosure EIA Positions for Legacy Cabinets ...
Страница 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Страница 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Страница 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Страница 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Страница 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Страница 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Страница 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Страница 358: ...358 Support Tools Manager ...
Страница 401: ...Controller Enclosure Modules 401 Removal and Replacement Figure 101 BBU Removal and Replacement ...
Страница 440: ...440 FCC Statements USA Only ...
Страница 466: ...466 Index ...