Managing Disk Array Capacity
243
M
a
na
ging
the
Di
sk
Array
on HP-UX
Selecting Disks for a LUN
When binding a LUN , you must select the disks that will be used. The capacity of the LUN
is determined by the number and capacity of the disks you select, and the RAID level.
When selecting disks for a LUN , consider the following:
•
To maximize high availability, select disks in different disk enclosures or on different
channels. Multiple disks in the same enclosure make a RAID 5 LUN vulnerable to an
enclosure failure. A RAID 1 or 0/1 LUN can survive an enclosure failure, as long as both
disks of a mirrored pair are not in the same enclosure. If you attempt to select disks in
the same enclosure or on the same channel when binding a LUN , you will be warned
that doing so may compromise high availability.
•
Select disks of the same capacity.Binding a LUN using different size disks will result in
unused capacity on the larger disks. For example, binding a 4-disk LUN that includes
two 9-Gbyte disks and two 18-Gbyte disks will result in a LUN with the capacity of four
9-Gbyte disks. Only 9 Gbytes of the larger disks will be used when creating the LUN .
•
Consider using more disks for RAID 5LUNs . This increases both performance and
storage efficiency. Because RAID 5 uses only one disk’s worth of capacity for parity,
more disks in the LUN will result in a greater percentage of the disk capacity used for
data. For example, in a 4-disk RAID 5LUN , 75% of the capacity is used for data (3 of 4).
Adding another disk to the LUN will increase the percentage of disk capacity used for
data to 80% (4 of 5).
Selecting Disks for a RAID 0/1 LUN
The order in which you select disks is important when creating a RAID 0/1 LUN. The first
half of the disks you select will be the primary disks, and the second half of the disks will
be the disk mirrors. To maintain data availability, the disk mirrors must be in a different
enclosure than the primary disks. This applies regardless of which tool you are using to
bind a RAID 0/1 LUN.
For example, in
Figure 85
a 4-disk RAID 0/1 LUN is being bound using one disk enclosure
on channel 1, and a second disk enclosure on channel 2. The correct order for selecting
disks is 1:2, 1:3, 2:2, 2:3. This selection order creates mirrored pairs of 1:2/2:2 and 1:3/2:3.
This maintains high availability because the primary disks are on channel 1, and the mirror
disks are on channel 2.
Содержание Surestore Disk Array 12h - And FC60
Страница 16: ...16 ...
Страница 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Страница 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Страница 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Страница 68: ...68 Capacity Management Features ...
Страница 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Страница 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Страница 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Страница 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Страница 134: ...134 Topologies for Windows NT and Windows 2000 Figure 45 Four Host Single Hub Single Disk Array Non HA Topology ...
Страница 136: ...136 Topologies for Windows NT and Windows 2000 Figure 47 Four Host Single Switch Dual Disk Array Non HA Topology ...
Страница 138: ...138 Topologies for Windows NT and Windows 2000 Figure 48 Direct Connect Single Host Single Disk Array HA Topology ...
Страница 140: ...140 Topologies for Windows NT and Windows 2000 Figure 50 Four Host Dual Hub Dual Disk Array HA Topology ...
Страница 142: ...142 Topologies for Windows NT and Windows 2000 ...
Страница 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Страница 159: ...Installing the Disk Array FC60 159 Installation Figure 55 Enclosure EIA Positions for Legacy Cabinets ...
Страница 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Страница 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Страница 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Страница 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Страница 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Страница 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Страница 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Страница 358: ...358 Support Tools Manager ...
Страница 401: ...Controller Enclosure Modules 401 Removal and Replacement Figure 101 BBU Removal and Replacement ...
Страница 440: ...440 FCC Statements USA Only ...
Страница 466: ...466 Index ...